Liquid Control
Contact Us Customer Support Request Information Engineering Toolbox Products Markets Applications eNewsletter Events and Links Press Room About Us Liquid Control


  Dispensing Technologies

  Metering Pump Technology
  Fixed- & Variable-Ratio Designs
  Mixer Technology
  Dispense Valve Technology
  Material Feed Systems
  How It Works

  Calculators & Conversion Tables

  Throughput Calculator
  P-200 Throughput Calculator
  C-500 Throughput Calculator
  Viscosity
  Fillers
  Vacuum
  Application Data & Calculations

  Industry Glossaries

  Abbreviations & Symbols
  Applications Glossaries

 

VACUUM

Vacuum Pump Sizing

To determine the vacuum pump size which is designated in cubic feet per minute (CFM), the following information is needed:

V = The volume of the tank(s) or vacuum chamber in cubic feet
T = The time required to achieve a specific vacuum level in minutes
F = A pump down factor for the specific vacuum pump which relates to the vacuum level required for the process

The formula for determining the vacuum pump size(S) is as follows:

S =

V x F

T




To determine the volume of standard tanks provided by Liquid Control, refer to the following chart:

Tank Size

Volume

3 Liter

0.11 cubic feet

5 Liter

0.18 cubic feet

2 Gallon

0.27 cubic feet

5 Gallon

0.67 cubic feet

10 Gallon

1.34 cubic feet

15 Gallon

2.00 cubic feet

30 Gallon

4.00 cubic feet

60 Gallon

8.00 cubic feet

To determine the pump down factor, locate the desired vacuum level on the vertical axis. Then find where this intersects on the curve(s) and go straight down to the horizontal axis to find the pump down factor (F).

Note: This graph is for a specific manufacturer of vacuum pumps and can vary for other types of vacuum pumps. For reference only.

Vacuum Conversion Examples

  1. What size vacuum pump is required for degassing a 30 gallon tank of material at a vacuum level of 10 Torr with the time required to achieve that vacuum level in the tank being 2 minutes?

    S =

    V x F

    T





    S =

    4.0 x 5





    S =

    10 CFM (minimum vacuum pump size)





    Note: The time required to thoroughly degas the material is dependent on the amount of air in the material, the viscosity of the material, the design of the agitation and/or recirculation system, and many other variables. The pump sizing above only considers the time required to achieve a certain vacuum level.

  2. How long will it take for a 6 CFM vacuum pump to achieve a I Torr vacuum level in a 5 gallon tank?

    S =

      V x F

    or

      T =

    V x F

      T

    S





    T =

    0.67 x 7

    6





    S =

    0.78 minutes





    Note: This assumes no vacuum leaks in the tank.

  3. What size vacuum pump is required for achieving a I Torr vacuum level within I minute in a 2'x 2'x 2' vacuum chamber?

    S =

    V x F

    T





    S =

    8 x 7

    1





    S =

    56 CFM (minimum vacuum pump size)






Vacuum Pump Sizing

Torr
or MM
Mercury

Micron

PSI

Inches
Mercury
Absolute

Inches
Mercury
Gauge

%
Vacuum

760.0

760,000

14.7

29.92

0.00

0.00

750.0

750,000

15.5

29.5

0.42

1.3

735.6

735,600

14.2

28.9

1.02

1.9

700.0

700,000

13.5

27.6

2.32

7.9

600.0

600,000

11.6

23.6

6.32

21.0

500.0

500,000

9.7

19.7

10.22

34.0

400.0

400,000

7.7

15.7

14.22

47.0

380.0

380,000

7.3

15.0

14.92

50.0

300.0

300,000

5.8

11.8

18.12

61.0

200.0

200,000

3.9

7.85

22.07

74.0

100.0

100,000

1.93

3.94

25.98

87.0

90.0

90,000

1.74

3.54

26.38

88.0

80.0

80,000

1.55

3.15

26.77

89.5

70.0

70,000

1.35

2.76

27.16

90.8

60.0

60,000

1.16

2.36

27.56

92.1

51.7

51,700

1.00

2.03

27.89

93.0

50.0

50,000

0.97

1.97

27.95

93.5

40.0

40,000

0.77

1.57

28.35

94.8

30.0

30,000

0.58

1.18

28.74

96.1

25.4

25,400

0.14912

1.00

28.92

96.6

20.0

20,000

0.39

0.785

29.14

97.4

10.0

10,000

0.193

0.394

29.53

98.7

7.6

7,600

0.147

0.299

29.62

99.0

1.0

1,000

0.01934

0.03937

29.88

99.9

0.75

750

0.0145

0.0295

29.89

99.9

0.10

100

0.00193

0.00394

29.916

99.99

0.01

10

0.000193

0.000394

29.9196

99.999

0.00

0

0

0

29.92

100

  Applications |  Products |  About Us |  Contact Us |  Request Information

 

 

Privacy Policy    Terms and Conditions    Copyright Policy

8400 Port Jackson Ave. NW - North Canton, Ohio 44720 Phone: 330-494-1313

About Us | Press Room | Events & Links | eNewsletter | Applications | Markets | Products | Request Information | Engineering Toolbox | Customer Support | Contact Us


The Liquid Control Website Has Been Optimized for Use in Internet Explorer 5.x and Later Versions

Best Viewed When Using a 1024 x 768 Resolution