Graco Inc.

Reactor E-10hp  High-Pressure Coating Equipment for Polyurea

Entry-level system for pure and hybrid polyurea coatings

Request Info
20130515_174156_sm

Grow your business with polyurea projects

If you'd like to add polyurea projects to your lineup, the Reactor E-10hp High Pressure Proportioner is a smart, affordable investment that can help your business grow.

The Reactor E-10hp provides the high pressure power and performance you need to spray polyurea coatings. It's lightweight and portable – and runs on residential power so you don’t need to invest in a generator.

Fast start-up times

With the system’s innovative boost heat and insulated tanks, material heats up fast so you’re up and running sooner. In fact, you're ready to spray in 20 minutes*, compared to over an hour startup time on a standard Reactor E-10. See chart below.

*With a 240V model


  • Ideal for small to medium projects such as terraces, pools, balconies,
    tanks, truck bedliners, secondary containment and waterproofing
  • Heats material fast for better productivity
  • Portable, compact and easy to maneuver
  • Easy to use
  • Uses standard residential electrical outlet
  • Affordable 

chart_Pres_Flow

This chart determines material output based on pressure and selected mix chamber. For example:

  • At 2200 psi with an AW2222 mix chamber, output is nearly 0.9 gpm
  • At 1800 psi with an AR2929 mix chamber, output is nearly 1 gpm 


E10h_chart_MaxTemp

Use this chart to determine which Reactor E-10 model is best suited for your application needs. This chart determines recirculation times and tank temperatures necessary to achieve your final spraying temperature.

  • Curved portion of line represents tank temperature.
  • Straight vertical portion of line represents Delta T of primary heaters.

To calculate necessary tank temps, subtract Delta T from your desired spray temperatures.

Reactor E-10hp
Maximum fluid working pressure
3000 psi
20.6 MPa, 206 bar
Maximum spray pressure: 120 V
2200 psi
15.2 MPa, 152 bar
Maximum spray pressure: 230 V
2500 psi
17.2 MPa, 172 bar
Maximum fluid temperature
170°F
77°C
Maximum ambient temperature
120°F
48°C
Maximum output
1 gal/min
3.8 liters/min
Output per cycle (ISO and RES)
0.0038 gallons/cycle
0.014 liters/cycle
Air inlet
1/4 in. quick-disconnect industrial type pin fitting
1/4 in. quick-disconnect industrial type pin fitting
Air outlet
1/4 npsm(m)
1/4 npsm(m)
Overpressure relief
Recirc/Spray valves automatically relieve excessive fluid pressure back to supply tanks
Recirc/Spray valves automatically relieve excessive fluid pressure back to supply tanks
Gun compressed air requirements
Fusion Gun (purge air and operating air): 4 scfm (0.112 m³/min)
Fusion Gun (purge air and operating air): 4 scfm (0.112 m³/min)
Maximum hose length
105 ft
32 m
Tank capacity each (nominal)
6 gal
22.7 liters
Weight (empty)
239 lb
108 kg
<b >Recommended Mix Chamber Sizes
Fusion® Air Purge
000, AW2222 (00 and 01 at reduced spray pressure)
000, AW2222 (00 and 01 at reduced spray pressure)
Probler® P2
AA (00 and 01 at reduced spray pressure)
AA (00 and 01 at reduced spray pressure)
<b >Electrical Requirements
120 V
120 VAC, 1 phase, 50/60 Hz, 3840 W; requires two separate, dedicated 20 A circuits. Full load peak amperage 16 A per circuit
120 VAC, 1 phase, 50/60 Hz, 3840 W; requires two separate, dedicated 20 A circuits. Full load peak amperage 16 A per circuit
230 V
230 VAC, 1 phase, 50/60 Hz, 5520 W; requires two separate, dedicated 15 A circuits. Full load peak amperage 12 A per circuit.
230 VAC, 1 phase, 50/60 Hz, 5520 W; requires two separate, dedicated 15 A circuits. Full load peak amperage 12 A per circuit.
Generator Size
120 V
5000 W minimum
5000 W minimum
230 V
7500 W minimum
7500 W minimum
Heater Power
120 V
3000 W during recirculation, 2000 W during pressure spray mode
3000 W during recirculation, 2000 W during pressure spray mode
230 V
4000 W during recirculation, 2760 W during pressure spray mode
4000 W during recirculation, 2760 W during pressure spray mode
Sound Pressure
In fast recirculation mode
71.3 dB(A)
71.3 dB(A)
Measure at 2500 psi (17 MPa, 172 bar), 1 gpm (3.8 lpm)
85.6 dB(A)
85.6 dB(A)
Sound Power Sound power measured per ISO-9614-2.
In fast recirculation mode
79.9 dB(A)
79.9 dB(A)
Measure at 2500 psi (17 MPa, 172 bar), 1 gpm (3.8 lpm)
93.3 dB(A)
93.3 dB(A)
Fluid Outlets
ISO Side
-5 JIC male
-5 JIC male
RES Side
-6 JIC male
-6 JIC male
Fluid Circulation Returns
ISO side
-5 JIC male
-5 JIC male
RES side
-6 JIC male
-6 JIC male
Hose Markings
ISO side
Red
Red
RES side
Blue
Blue
Wetted Parts
Wetted parts on all models
Aluminum, stainless steel, carbon steel, brass, carbide, chrome, chemically resistant o-rings, PTFE, ultra-high molecular weight polyethylene
Aluminum, stainless steel, carbon steel, brass, carbide, chrome, chemically resistant o-rings, PTFE, ultra-high molecular weight polyethylene
All other brand names or marks are used for identification purposes and are trademarks of their respective owners.



Reactor E-10hp
Maximum fluid working pressure
3000 psi
20.6 MPa, 206 bar
Maximum spray pressure: 120 V
2200 psi
15.2 MPa, 152 bar
Maximum spray pressure: 230 V
2500 psi
17.2 MPa, 172 bar
Maximum fluid temperature
170°F
77°C
Maximum ambient temperature
120°F
48°C
Maximum output
1 gal/min
3.8 liters/min
Output per cycle (ISO and RES)
0.0038 gallons/cycle
0.014 liters/cycle
Air inlet
1/4 in. quick-disconnect industrial type pin fitting
1/4 in. quick-disconnect industrial type pin fitting
Air outlet
1/4 npsm(m)
1/4 npsm(m)
Overpressure relief
Recirc/Spray valves automatically relieve excessive fluid pressure back to supply tanks
Recirc/Spray valves automatically relieve excessive fluid pressure back to supply tanks
Gun compressed air requirements
Fusion Gun (purge air and operating air): 4 scfm (0.112 m³/min)
Fusion Gun (purge air and operating air): 4 scfm (0.112 m³/min)
Maximum hose length
105 ft
32 m
Tank capacity each (nominal)
6 gal
22.7 liters
Weight (empty)
239 lb
108 kg
Recommended Mix Chamber Sizes
Fusion® Air Purge
000, AW2222 (00 and 01 at reduced spray pressure)
000, AW2222 (00 and 01 at reduced spray pressure)
Probler® P2
AA (00 and 01 at reduced spray pressure)
AA (00 and 01 at reduced spray pressure)
Electrical Requirements
120 V
100–120 VAC, 1 phase, 50/60 Hz, 3840 W; requires two separate, dedicated 20 A circuits. Full load peak amperage 16 A per circuit
100–120 VAC, 1 phase, 50/60 Hz, 3840 W; requires two separate, dedicated 20 A circuits. Full load peak amperage 16 A per circuit
230 V
200–230 VAC, 1 phase, 50/60 Hz, 5520 W; requires two separate, dedicated 15 A circuits. Full load peak amperage 12 A per circuit.
200–230 VAC, 1 phase, 50/60 Hz, 5520 W; requires two separate, dedicated 15 A circuits. Full load peak amperage 12 A per circuit.
Generator Size
120 V
5000 W minimum
5000 W minimum
230 V
7500 W minimum
7500 W minimum
Heater Power
120 V
3000 W during recirculation, 2000 W during pressure spray mode
3000 W during recirculation, 2000 W during pressure spray mode
230 V
4000 W during recirculation, 2760 W during pressure spray mode
4000 W during recirculation, 2760 W during pressure spray mode
Sound Pressure
In fast recirculation mode
71.3 dB(A)
71.3 dB(A)
Measure at 2500 psi (17 MPa, 172 bar), 1 gpm (3.8 lpm)
85.6 dB(A)
85.6 dB(A)
Sound Power (Measured per ISO-9614-2)
In fast recirculation mode
79.9 dB(A)
79.9 dB(A)
Measure at 2500 psi (17 MPa, 172 bar), 1 gpm (3.8 lpm)
93.3 dB(A)
93.3 dB(A)
Fluid Outlets
ISO Side
-5 JIC male
-5 JIC male
RES Side
-6 JIC male
-6 JIC male
Fluid Circulation Returns
ISO side
-5 JIC male
-5 JIC male
RES side
-6 JIC male
-6 JIC male
Hose Markings
ISO side
Red
Red
RES side
Blue
Blue
Wetted Parts
Wetted parts on all models
Aluminum, stainless steel, carbon steel, brass, carbide, chrome, chemically resistant o-rings, PTFE, ultra-high molecular weight polyethylene
Aluminum, stainless steel, carbon steel, brass, carbide, chrome, chemically resistant o-rings, PTFE, ultra-high molecular weight polyethylene
All other brand names or marks are used for identification purposes and are trademarks of their respective owners.