Graco Inc.

호라이즌 유체 관리 시스템  전자식 유체 관리 시스템

복수 서비스 베이에 대한 일괄 디스펜싱

정보 요청
113551 113553 Horizon Keypads
  • 여러 기술자가 동시에 디스펜스 할 수 있습니다
  • 모든 설비에서 구성 및 확장이 용이
  • 기술자의 생산성을 증대합니다
  • 암호로 보호하여 무단 디스펜싱 방지
  • 재고 수준을 추적하여 작업자에게 재고 부족 상태를 경고함으로써 재고 품절 상황을 최소화 합니다

Horizon
System Specifications
40 maximum
Control Modules in a system (1 Master only, plus 39 Slave)
Control Modules in a system (1 Master only, plus 39 Slave)
40 maximum
Keypads in a system (1 keypad per Control Module; Administrators Keypad must be connected to the Master Control Module)
Keypads in a system (1 keypad per Control Module; Administrators Keypad must be connected to the Master Control Module)
240 maximum
Solenoids in a system (40 Control Modules, 6 ports each)
Solenoids in a system (40 Control Modules, 6 ports each)
240 maximum
Meters in a system (40 Control Modules, 6 ports each)
Meters in a system (40 Control Modules, 6 ports each)
10 maximum
Fluids supported by a system
Fluids supported by a system
99 maximum
Dispense Areas (reel banks)
Dispense Areas (reel banks)
100 maximum
Operator Names/PIN numbers
Operator Names/PIN numbers
668 maximum
Dispense Records stored
Dispense Records stored
12 maximum
Simultaneous Dispenses (same and/or different fluids)
Simultaneous Dispenses (same and/or different fluids)
12 maximum
Jobs Waiting in Queue
Jobs Waiting in Queue
1 maximum
Printer per system (must be connected to Master Control Module) OR Attached Computer per system (must be connected to Master Control Module)
Printer per system (must be connected to Master Control Module) OR Attached Computer per system (must be connected to Master Control Module)
Control Module Ports
6
Solenoid Ports per Control Module
Solenoid Ports per Control Module
6
Pulse Meter Ports per Control Module
Pulse Meter Ports per Control Module
1
Port for Keypad per Control Module
Port for Keypad per Control Module
1
Port for printer or computer per Master Control Module
Port for printer or computer per Master Control Module
1
Bar code reader per control module
Bar code reader per control module
Voltage Input
110 Volts AC, 50/60 Hz, 2 amps maximum draw
110 Volts AC, 50/60 Hz, 2 amps maximum draw
220 Volts AC, 50/60 Hz, 1 amp maximum draw
220 Volts AC, 50/60 Hz, 1 amp maximum draw
Environment
Operating Temperature Range
40–140°F ambient
4–60°C ambient
Humidity Range
0–95% non-condensing
0–95% non-condensing
Preset or Free-flow Limits
999.9 Units
Maximum Preset or free-flow dispense
Maximum Preset or free-flow dispense
0.5 Units
Minimum Preset dispense
Minimum Preset dispense
Dispense Units of Measure
liters, quarts, gallons or pints (configurable for each fluid)
liters, quarts, gallons or pints (configurable for each fluid)
Inventory Units of Measure
liters or gallons (dependent upon dispense units chosen)
liters or gallons (dependent upon dispense units chosen)
Maximum Cable Lengths
From Keypad to Control Module
50 ft
15.3 m
From Solenoid to Control Module
50 ft
15.3 m
From Pulse Meter to Control Module
50 ft
15.3 m
From Printer or Computer to Master Control Module
50 ft
15.3 m
From one end of the Control Module Network to the other end (daisy-chained)
2000 ft
610 m