Graco Inc.

SaniForce 2150 Double Diaphragm Pump

2 Inch Air-Operated Double Diaphragm Pump

2 inch air-operated double diaphragm with flow rates up to 150 gpm (568 lpm)

Dónde comprarSolicitar información

Graco’s SaniForce 2150 air-operated diaphragm pumps have one of the best, most durable, lube-free air valves in the industry. Ideal for applications requiring high flow rates and portability, Graco’s dependable diaphragm pumps offer a wide range of food-grade elastomers including Santoprene, PTFE and overmolded EPDM/PTFE.

19273
  • 2-1/2 in (63.5 mm) Tri-clamp connection
  • Flow rates up to 150 gpm (568 lpm)
  • Fluid pressure to 120 psi (8.4 bar, 0.84 MPa)
  • All fluid contact materials are FDA-Compliant and meet the United States Code of Federal Regulations (CFR) Title 21
11585

Patented, lube-free air valve

  • Three-way pilot valve for no-stick operation
  • Long-lasting 16 Series stainless steel rod design for long life and corrosion resistance
  • 1040, 1590 and 2150 SaniForce pumps use common center sections
  • 100% externally serviceable air valve
19271

PTFE/EPDM Overmolded Diaphragms

  • Overmolded diaphragm plate with PTFE on the fluid side and EPDM on the air side on Graco's PTFE/EPDM diaphragms so there's no place to harbor bacteria
  • Improve wear and diaphragm life with no exposed diaphragm plate on the fluid side
  • Longer diaphragm life in abrasive applications that still require PTFE
  • Available on the SaniForce 1040, 1590, 2150 and SaniForce HS 1590 and 3150
SaniForce 2150 Diaphragm Pumps
Maximum fluid working pressure
120 psi
8 bar, 0.8 MPa
Air pressure operating range
20–120 psi
1.4–8 bar, 0.14–0.8 MPa
Maximum air consumption
175 scfm
3
Air consumption at 70 psi, 50 gpm
70 scfm
3
Maximum free-flow delivery
160 gpm
568 lpm
Maximum pump speed
165 cpm
165 cpm
Gallons/liters per cycle*
0.97 g
3.7 l
Maximum suction lift
29 ft wet, 16 ft dry
8.8 m wet, 4.9 m dry
Maximum size pumpable solids
1/4 in
6.3 mm
Noise Data**
Maximum Noise Level at 100 psi (7 bar, 0.7 MPa), full flow
95 dB(A)
95 dB(A)
Sound power level
102 dB(A)
102 dB(A)
Noise level at 70 psi (4.8 bar, 0.48 MPa), 50 cpm
84 dB(A)
84 dB(A)
Maximum fluid operating temperature is based on the following maximum diaphragm, ball, and seat temperature ratings
PTFE
220°F
104°C
Santoprene®
180°F
82°C
EPDM
275°F
135°C
Polychloroprene
200°F
93°C
Stainless Steel
250°F
121°C
Inlet/Outlet Sizes
Air inlet size
0.5 in npt(f)
0.5 in npt(f)
Fluid inlet size
2.5 in sanitary flange
2.5 in sanitary flange
Fluid outlet size
2.5 in sanitary flange
2.5 in sanitary flange
Wetted Parts***
All fluid contact materials are FDA-compliant and meet the United States Code of Federal Regulations (CFR) Title 21, Section 177.
Wetted materials on all models
316 stainless steel
316 stainless steel
Wetted materials depending on model
EPDM, Polychloroprene, PTFE, Santoprene
EPDM, Polychloroprene, PTFE, Santoprene
CAUTION: Santoprene may be used only with non-fatty, non-oily foods or alcohols up to 15%
Non-wetted external parts
300 series stainless steel, aluminum (A380), polyester (labels), LDPE foam (gasket)
300 series stainless steel, aluminum (A380), polyester (labels), LDPE foam (gasket)
Weight
FD2 Models
147 lb
66.7 kg
FA1 Models
141 lb
64 kg
Loctite® is a registered trademark of the Loctite Corporation.