G3 Pro
G3™ Pro Oil Lubrication Pump, 90-240 VAC, 8 Litre, Low Level with Controller, DIN
Part Number: 96G081
G3 Pro
G3™ Pro Oil Lubrication Pump, 90-240 VAC, 8 Litre, Low Level with Controller, DIN
Part Number: 96G081
Extend machinery life, reduce operating costs and increase productivity with a Graco G3 today! The G3 Pro has a flexible design that works with injector-based and series progressive systems. A cost-effective pump designed to serve multiple markets and applications. Includes one adjustable pump eleme...
More InfoIf you’re not finding the information you need, ask one of our experts.
Ask an ExpertFeatures
Product BrochureExtend machinery life, reduce operating costs and increase productivity with a Graco G3 today! The G3 Pro has a flexible design that works with injector-based and series progressive systems. A cost-effective pump designed to serve multiple markets and applications. Includes one adjustable pump element – standard, plus room for two more. The ultimate in flexibility – for a high value, custom fit on your application.
- Built-in controller with selectable pump on/pump off timer
- Low level indicator provides low warning and shut-down alarm
- Manual run initiates lube cycle on-demand (remote option also available)
- Password protection safeguards settings
- Pre-lube function can initiate lube cycle on start-up
Specifications & Documents
Technical Specifications
Convert to ImperialAlarm Relay Inductive Maximum Operating Voltage (VDC) | 220 |
---|---|
Alarm Relay Inductive Maximum Switching Capacity | 25 VA;30 W |
Alarm Relay Inductive Minimum Permissible Load | 10 ?A;10m VDC |
Alarm Relay Inductive Rated Load (A) | 1 |
Alarm Relay Resistive Maximum Operating Current (A) | 3 |
Alarm Relay Resistive Maximum Switching Capacity | 50 VA;60 W |
Alarm Relay Resistive Minimum Permissible Load | 10 µA;10m VDC |
Alarm Relay Resistive Rated Load (A) | 2 |
Application | On-Road Vehicles, Off-Road Equipment |
Compatible Material | Oil |
Compatible Metering Device | Series Progressive |
Control Options | Pro |
Fluid Outlet Size (in) | 0.25 |
Fluid Outlet Thread Gender | Female |
Fluid Outlet Thread Type | NPSF |
For Use With | Injector-Based Systems, Series Progressive Systems |
IP Rating | IP69K |
Includes | Low Level |
Input Cycle Rate (Hz) | 8 |
Input Impedance | 1.1 |
Input Load Current (mA @ 24 VDC) | 22 |
Input Maximum Off Current (mA) | 1.5 |
Input Maximum Residual Voltage (V) | 4 |
Input Required Switch Type | Normally Open |
Input Response Time (ms) | 60 |
Input Sensor Voltage (VDC) | 24 |
Low Level Carry Current (A) | 1.2 |
Low Level Contact Rating (W) | 10 |
Low Level Switch Rating (VDC) | 200 |
Low Level Switching Current (A) | 0.5 |
Maximum Fill Inlet Pressure (psi) | 5000 |
Maximum NLGI Grade | #2 |
Maximum Run Time (min) | 30 |
Maximum Voltage (V ac) | 264 |
Maximum Working Pressure (MPa) | 35.1 |
Maximum Working Pressure (psi) | 5100 |
Minimum Voltage (V AC) | 88 |
Minimum cST Grade (cST) | 40 |
Model | G3 |
Number of Machine Count Sensor Inputs | 1 |
Number of Pressure and Cycle Sensor Inputs | 3 |
Number of Pump Elements | Up to 3 |
Overall Depth (in) | 10 |
Overall Height (in) | 18.5 |
Overall Width (in) | 9.25 |
Power Connection Type | DIN |
Power Type | Electric |
Pump Output with 0 Spacers (cu in/min) | 0.25 |
Pump Output with 1 Spacer (cu in/min) | 0.18 |
Pump Output with 2 Spacers (cu in/min) | 0.12 |
Reservoir Size (gal) | 2.11 |
Reservoir Size (l) | 8 |
Series | Pro |
Type | Electric Piston Pump |
Vent Valve Maximum Operating Current (A) | 2 |
Vent Valve Maximum Operating Power (W) | 48 |
Vent Valve Output Voltage (VDC) | 24 |
Voltage (V AC) | 90-240 |
Voltage (V) | 90-240 VAC |
Weight (lb) | 13.3 |
Wetted Material | Nylon, Trogamid T5004-060, Zinc-Plated Steel, Carbon Steel, Alloy Steel, Stainless Steel, Nitrile Rubber, Bronze, Nickel Plated Alnico, Chemically Lubricated Acetal, Aluminium, PTFE, Grillamid |
Alarm Relay Inductive Maximum Operating Voltage (VDC) | 220 |
Alarm Relay Inductive Maximum Switching Capacity | 25 VA;30 W |
Alarm Relay Inductive Minimum Permissible Load | 10 ?A;10m VDC |
Alarm Relay Inductive Rated Load (A) | 1 |
Alarm Relay Resistive Maximum Operating Current (A) | 3 |
Alarm Relay Resistive Maximum Switching Capacity | 50 VA;60 W |
Alarm Relay Resistive Minimum Permissible Load | 10 µA;10m VDC |
Alarm Relay Resistive Rated Load (A) | 2 |
Application | On-Road Vehicles, Off-Road Equipment |
Compatible Material | Oil |
Compatible Metering Device | Series Progressive |
Control Options | Pro |
Fluid Outlet Size (in) | 0.25 |
Fluid Outlet Size (mm) | 6.3500 |
Fluid Outlet Thread Gender | Female |
Fluid Outlet Thread Type | NPSF |
For Use With | Injector-Based Systems, Series Progressive Systems |
IP Rating | IP69K |
Includes | Low Level |
Input Cycle Rate (Hz) | 8 |
Input Impedance | 1.1 |
Input Load Current (mA @ 24 VDC) | 22 |
Input Maximum Off Current (mA) | 1.5 |
Input Maximum Residual Voltage (V) | 4 |
Input Required Switch Type | Normally Open |
Input Response Time (ms) | 60 |
Input Sensor Voltage (VDC) | 24 |
Low Level Carry Current (A) | 1.2 |
Low Level Contact Rating (W) | 10 |
Low Level Switch Rating (VDC) | 200 |
Low Level Switching Current (A) | 0.5 |
Maximum Fill Inlet Pressure (bar) | 344.7 |
Maximum Fill Inlet Pressure (kPa) | 34470 |
Maximum Fill Inlet Pressure (psi) | 5000 |
Maximum NLGI Grade | #2 |
Maximum Run Time (min) | 30 |
Maximum Voltage (V ac) | 264 |
Maximum Working Pressure (MPa) | 35.1 |
Maximum Working Pressure (bar) | 351.6 |
Maximum Working Pressure (kPa) | 35160 |
Maximum Working Pressure (psi) | 5100 |
Minimum Voltage (V AC) | 88 |
Minimum cST Grade (cST) | 40 |
Model | G3 |
Number of Machine Count Sensor Inputs | 1 |
Number of Pressure and Cycle Sensor Inputs | 3 |
Number of Pump Elements | Up to 3 |
Overall Depth (cm) | 25.4 |
Overall Depth (mm) | 254 |
Overall Height (cm) | 47 |
Overall Height (mm) | 470 |
Overall Width (cm) | 23.5 |
Overall Width (mm) | 235 |
Power Connection Type | DIN |
Power Type | Electric |
Reservoir Size (l) | 8 |
Series | Pro |
Type | Electric Piston Pump |
Vent Valve Maximum Operating Current (A) | 2 |
Vent Valve Maximum Operating Power (W) | 48 |
Vent Valve Output Voltage (VDC) | 24 |
Voltage (V AC) | 90-240 |
Voltage (V) | 90-240 VAC |
Weight (kg) | 6 |
Wetted Material | Nylon, Trogamid T5004-060, Zinc-Plated Steel, Carbon Steel, Alloy Steel, Stainless Steel, Nitrile Rubber, Bronze, Nickel Plated Alnico, Chemically Lubricated Acetal, Aluminium, PTFE, Grillamid |