Graco Inc.

PCF 计量系统  精确连续流计量与分配系统

先进的闭环技术,可实现高度精确的连续分配

购买地点小帮手咨询信息

卓越的流量控制功能可减少材料浪费

固瑞克 PCF 计量系统配合供料系统与机器人平台使用,可实现高度精确的连续分配。 闭环技术根据材料温度、粘度、分配流速或自动装置速度的变化进行实时调整,实现高度精确的连续分配。系统组件包括:高级显示模块、流体盘、固瑞克 CAN 电缆和网关模块。

可处理材料:

• 常温、温胶型及热熔粘接材料,加热温度最高可达 400°F (204°C)
• 低粘度至高粘度材料
• 流量范围无限制

Monitor 1

For drivetrain gasketing, the Graco Dispense Analyzer helps you find and correct the smallest of errors - before your customers find them for you. Learn more!

Graco PCF Metering System

新一代精确计量系统

  • 闭路实时控制可实现高度精确的连续分配——可提高零件质量并减少材料浪费
  • 直观的用户界面,简化了安装,缩短了培训时间
  • 集成的 USB 接口便于下载数据——以便进一步分析
  • 支持多喷枪,提高生产效率——最多支持四支喷枪
  • 紧凑的模块化设计——易于安装、整成与维修
  • 降低使用成本——与注射式计量缸相比更少的易损件,维护简单

PCF
Minumum Flow Rates
25 cc/min with high-resolution (ambient) helical flow meter, 50 cc/min with heated helical flow meter
25 cc/min with high-resolution (ambient) helical flow meter, 50 cc/min with heated helical flow meter
Maximum Flow Rates
7500 cc/min with high-resolution (ambient) helical flow meter, 22,500 cc/min with heated helical flow meter, 37,500 cc/min with separate flow meter
7500 cc/min with high-resolution (ambient) helical flow meter, 22,500 cc/min with heated helical flow meter, 37,500 cc/min with separate flow meter
Minimum Fluid Working Pressure (at regulator outlet)
100 psi
0.7 MPa/7.0 bar
Air Supply Pressure Range
60–120 psi, 10 Micron filtration required
0.4 – 0.8 MPa/4.1 – 8.3 bar, 10 Micron filtration required
Fluid Filtration Required
30 mesh minimum
500 micron minimum
Viscosity Range of Fluids
10000 to 1000000 cps with helical flow meter
10000 to 1000000 cps with helical flow meter
Minimum Dispensed Shot Size
3 cc with high-resolution (ambient) helical flow meter, 6 cc with heated helical flow meter
3 cc with high-resolution (ambient) helical flow meter, 6 cc with heated helical flow meter
Wetted Parts (meters and fluid plates)
303, 304, 321, 17–4 stainless steel, tungsten carbide, PTFE, steel, fluoroelastomer
303, 304, 321, 17–4 stainless steel, tungsten carbide, PTFE, steel, fluoroelastomer
Power Supply Voltage Range
100–240 Vac, 50–60 Hz, single phase
100–240 Vac, 50–60 Hz, single phase
Operating Humidity Range
0 – 90% non-condensing
0 – 90% non-condensing
Operating Temperature Range
Control Center
40°F to 120°F
4°C to 49°C
Heated Fluid Plate
40°F to 400°F
4°C to 204°C
204 CAmbient Fluid Plate
40°F to 120°F
4°C to 49°C
Power Requirements
100–240 Vac
full load 1.4A, fuse rating-2.5A
full load 1.4A, fuse rating-2.5A
240 Vac
full load-4A, fuse rating-4A
full load-4A, fuse rating-4A
Maximum Fluid working pressure
Feed Pressure to Fluid Plate (cartridge regulator)
6000 psi
41.1 MPa/414 bar
Feed Pressure to Fluid Plate (mastic regulator)
5000 psi
34.5 MPa/345 bar
At regulator outlet
4500 psi
31.0 MPa/310 bar
At regulator outlet with electric heat components
3500 psi
24.1 MPa/241 bar