G3 Pro
G3™ Pro Grease Lubrication Pump, 90-240 VAC, 2 Litre, Follower Plate, DIN
Part Number: 96G014
G3 Pro
G3™ Pro Grease Lubrication Pump, 90-240 VAC, 2 Litre, Follower Plate, DIN
Part Number: 96G014
Extend machinery life, reduce operating costs and increase productivity with a Graco G3 today! The G3 Pro has a flexible design that works with injector-based and series progressive systems. A cost-effective pump designed to serve multiple markets and applications. Includes one adjustable pump eleme...
More InfoFeatures
Product BrochureExtend machinery life, reduce operating costs and increase productivity with a Graco G3 today! The G3 Pro has a flexible design that works with injector-based and series progressive systems. A cost-effective pump designed to serve multiple markets and applications. Includes one adjustable pump element - standard, plus room for two more. The ultimate in flexibility - for a high value, custom fit on your application.
- Built-in controller with selectable pump on/pump off timer
- Low level indicator provides low warning and shut-down alarm
- Manual run initiates lube cycle on-demand (remote option also available)
- Password protection safeguards settings
- Pre-lube function can initiate lube cycle on start-up
Specifications & Documents
Technical Specifications
Convert to ImperialAlarm Relay Inductive Maximum Operating Current (A) | 1.5 |
---|---|
Alarm Relay Inductive Maximum Switching Capacity | 25 VA;30 W |
Alarm Relay Inductive Minimum Permissible Load | 10 ?A;10m VDC |
Alarm Relay Inductive Rated Load (A) | 0.2 |
Alarm Relay Resistive Maximum Operating Current (A) | 3 |
Alarm Relay Resistive Maximum Switching Capacity | 50 VA;60 W |
Alarm Relay Resistive Minimum Permissible Load | 10 µA;10m VDC |
Alarm Relay Resistive Rated Load (A) | 0.4 |
Alarm relay inductive maximum operating voltage (VAC) | 250 |
Alarm relay resistive maximum operating voltage (VAC) | 250 |
Application | On-Road Vehicles, Off-Road Equipment |
Compatible Material | Grease |
Compatible Metering Device | Series Progressive |
Control Options | Pro |
Fluid Outlet Size (in) | 0.25 |
Fluid Outlet Thread Gender | Female |
Fluid Outlet Thread Type | NPSF |
For Use With | Injector-Based Systems, Series Progressive Systems |
IP Rating | IP69K |
Includes | Follower Plate, Low Level |
Input Cycle Rate (Hz) | 8 |
Input Impedance | 1.1 |
Input Maximum Residual Voltage (V) | 4 |
Input Required Switch Type | Normally open |
Input load current (mA @ 24 VDC) | 22 |
Input maximum Off current (mA) | 1.5 |
Input response time (ms) | 60 |
Input sensor voltage (VDC) | 24 |
Low Level Carry Current (A) | 1.2 |
Low Level Contact Rating (W) | 10 |
Low Level Switching Current (A) | 0.5 |
Low level switch rating (VDC) | 200 |
Maximum Fill Inlet Pressure (psi) | 5000 |
Maximum NLGI Grade | #2 |
Maximum Run Time (min) | 30 |
Maximum Voltage (V ac) | 264 |
Maximum Working Pressure (MPa) | 35.1 |
Maximum Working Pressure (psi) | 5100 |
Minimum Voltage (V ac) | 88 |
Model | G3 |
Number of Machine Count Sensor Inputs | 1 |
Number of Pressure and Cycle Sensor Inputs | 3 |
Number of Pump Elements | Up to 3 |
Overall Depth (in) | 9 |
Overall Height (in) | 13.25 |
Overall Width (in) | 8 |
Power Connection Type | DIN |
Power Type | Electric |
Pump Output with 0 Spacers (cu in/min) | 0.25 |
Pump Output with 1 Spacer (cu in/min) | 0.18 |
Pump Output with 2 Spacers (cu in/min) | 0.12 |
Reservoir Size (L) | 2 |
Reservoir Size (gal) | 0.528 |
Series | Pro |
Type | Electric Piston Pump |
Vent Valve Maximum Operating Current (A) | 2 |
Vent Valve Maximum Operating Power (W) | 48 |
Vent valve output voltage (VDC) | 24 |
Voltage (V ac) | 90-240 |
Voltage (V) | 90-240 VAC |
Weight (lb) | 13.3 |
Wetted Material | Nylon, Trogamid T5004-060, Zinc-Plated Steel, Carbon Steel, Alloy Steel, Stainless Steel, Nitrile Rubber, Bronze, Nickel-Plated Alnico, Chemically Lubricated Acetal, Aluminium, PTFE, Grilamid |
Alarm Relay Inductive Maximum Operating Current (A) | 1.5 |
Alarm Relay Inductive Maximum Switching Capacity | 25 VA;30 W |
Alarm Relay Inductive Minimum Permissible Load | 10 ?A;10m VDC |
Alarm Relay Inductive Rated Load (A) | 0.2 |
Alarm Relay Resistive Maximum Operating Current (A) | 3 |
Alarm Relay Resistive Maximum Switching Capacity | 50 VA;60 W |
Alarm Relay Resistive Minimum Permissible Load | 10 µA;10m VDC |
Alarm Relay Resistive Rated Load (A) | 0.4 |
Alarm relay inductive maximum operating voltage (VAC) | 250 |
Alarm relay resistive maximum operating voltage (VAC) | 250 |
Application | On-Road Vehicles, Off-Road Equipment |
Compatible Material | Grease |
Compatible Metering Device | Series Progressive |
Control Options | Pro |
Fluid Outlet Size (in) | 0.25 |
Fluid Outlet Size (mm) | 6.3500 |
Fluid Outlet Thread Gender | Female |
Fluid Outlet Thread Type | NPSF |
For Use With | Injector-Based Systems, Series Progressive Systems |
IP Rating | IP69K |
Includes | Follower Plate, Low Level |
Input Cycle Rate (Hz) | 8 |
Input Impedance | 1.1 |
Input Maximum Residual Voltage (V) | 4 |
Input Required Switch Type | Normally open |
Input load current (mA @ 24 VDC) | 22 |
Input maximum Off current (mA) | 1.5 |
Input response time (ms) | 60 |
Input sensor voltage (VDC) | 24 |
Low Level Carry Current (A) | 1.2 |
Low Level Contact Rating (W) | 10 |
Low Level Switching Current (A) | 0.5 |
Low level switch rating (VDC) | 200 |
Maximum Fill Inlet Pressure (bar) | 344.7 |
Maximum Fill Inlet Pressure (kPa) | 34470 |
Maximum Fill Inlet Pressure (psi) | 5000 |
Maximum NLGI Grade | #2 |
Maximum Run Time (min) | 30 |
Maximum Voltage (V ac) | 264 |
Maximum Working Pressure (MPa) | 35.1 |
Maximum Working Pressure (bar) | 351.6 |
Maximum Working Pressure (kPa) | 35160 |
Maximum Working Pressure (psi) | 5100 |
Minimum Voltage (V ac) | 88 |
Model | G3 |
Number of Machine Count Sensor Inputs | 1 |
Number of Pressure and Cycle Sensor Inputs | 3 |
Number of Pump Elements | Up to 3 |
Overall Depth (cm) | 22.9 |
Overall Depth (mm) | 229 |
Overall Height (cm) | 33.7 |
Overall Height (mm) | 337 |
Overall Width (cm) | 20.3 |
Overall Width (mm) | 203 |
Power Connection Type | DIN |
Power Type | Electric |
Reservoir Size (L) | 2 |
Series | Pro |
Type | Electric Piston Pump |
Vent Valve Maximum Operating Current (A) | 2 |
Vent Valve Maximum Operating Power (W) | 48 |
Vent valve output voltage (VDC) | 24 |
Voltage (V ac) | 90-240 |
Voltage (V) | 90-240 VAC |
Weight (kg) | 6 |
Wetted Material | Nylon, Trogamid T5004-060, Zinc-Plated Steel, Carbon Steel, Alloy Steel, Stainless Steel, Nitrile Rubber, Bronze, Nickel-Plated Alnico, Chemically Lubricated Acetal, Aluminium, PTFE, Grilamid |