ACS Module Advanced Control System
Use with E-Flo pumps and 3rd party variable frequency drives (VFD’s)
Graco’s ACS Module provides optimal control of paint circulating systems when used with E-Flo pumps and 3rd party variable frequency drives (VFD’s).
- Provides optimized run cam profile for reduced pressure fluctuations
- Integrated pressure control mode available for on-demand fluid supply
- Increase energy savings with on/off production control modes
- Real-time monitoring and reporting of fluid pressure and flow rate
Εγχειρίδια
Έντυπο υλικό
Άλλοι πόροι
- CAD Drawing (2D) - 24H372 - .zip (Μόνο Αγγλικά)
- CAD Drawing (3D) - 24H372 - .zip (Μόνο Αγγλικά)
- ACS Software Download File
24H372 ACS Module | |
US
Metric
|
|
Inputs | |
Power |
20-30 Vdc, 200mA, reverse polarity protected
20-30 Vdc, 200mA, reverse polarity protected
|
Analog inputs |
2 inputs for 4-20mA current loop sensing. Inputs protected from direct application of 24 Vdc.
2 inputs for 4-20mA current loop sensing. Inputs protected from direct application of 24 Vdc.
|
Digital inputs: |
4 inputs: TDC, Position Sensor, AutoSleep, and Reset. Digital inputs are 24V logic level NPN.
4 inputs: TDC, Position Sensor, AutoSleep, and Reset. Digital inputs are 24V logic level NPN.
|
Outputs | |
4-20 mA loop |
2 channels, adjustable offset and span.
2 channels, adjustable offset and span.
|
Digital outputs |
2 open contact, normally open relay outputs, 24V, 1A, used for BPR control and Drive Enable.
2 open contact, normally open relay outputs, 24V, 1A, used for BPR control and Drive Enable.
|
Communications |
1 Ethernet port and 1 RS485 port
1 Ethernet port and 1 RS485 port
|
Ambient Conditions | |
Operating temperature range |
32-121°F
0-50°C
|
Operating humidity |
10-90% relative humidity, non-condensing
10-90% relative humidity, non-condensing
|