- 여러 기술자가 동시에 디스펜스 할 수 있습니다
- 모든 설비에서 구성 및 확장이 용이
- 기술자의 생산성을 증대합니다
- 암호로 보호하여 무단 디스펜싱 방지
- 재고 수준을 추적하여 작업자에게 재고 부족 상태를 경고함으로써 재고 품절 상황을 최소화 합니다
호라이즌 유체 관리 시스템 전자식 유체 관리 시스템
복수 서비스 베이에 대한 일괄 디스펜싱

자료
Horizon | |
System Specifications | |
40 maximum |
Control Modules in a system (1 Master only, plus 39 Slave)
Control Modules in a system (1 Master only, plus 39 Slave)
|
40 maximum |
Keypads in a system (1 keypad per Control Module; Administrators Keypad must be connected to the Master Control Module)
Keypads in a system (1 keypad per Control Module; Administrators Keypad must be connected to the Master Control Module)
|
240 maximum |
Solenoids in a system (40 Control Modules, 6 ports each)
Solenoids in a system (40 Control Modules, 6 ports each)
|
240 maximum |
Meters in a system (40 Control Modules, 6 ports each)
Meters in a system (40 Control Modules, 6 ports each)
|
10 maximum |
Fluids supported by a system
Fluids supported by a system
|
99 maximum |
Dispense Areas (reel banks)
Dispense Areas (reel banks)
|
100 maximum |
Operator Names/PIN numbers
Operator Names/PIN numbers
|
668 maximum |
Dispense Records stored
Dispense Records stored
|
12 maximum |
Simultaneous Dispenses (same and/or different fluids)
Simultaneous Dispenses (same and/or different fluids)
|
12 maximum |
Jobs Waiting in Queue
Jobs Waiting in Queue
|
1 maximum |
Printer per system (must be connected to Master Control Module) OR Attached Computer per system (must be connected to Master Control Module)
Printer per system (must be connected to Master Control Module) OR Attached Computer per system (must be connected to Master Control Module)
|
Control Module Ports | |
6 |
Solenoid Ports per Control Module
Solenoid Ports per Control Module
|
6 |
Pulse Meter Ports per Control Module
Pulse Meter Ports per Control Module
|
1 |
Port for Keypad per Control Module
Port for Keypad per Control Module
|
1 |
Port for printer or computer per Master Control Module
Port for printer or computer per Master Control Module
|
1 |
Bar code reader per control module
Bar code reader per control module
|
Voltage Input | |
110 Volts AC, 50/60 Hz, 2 amps maximum draw
110 Volts AC, 50/60 Hz, 2 amps maximum draw
|
|
220 Volts AC, 50/60 Hz, 1 amp maximum draw
220 Volts AC, 50/60 Hz, 1 amp maximum draw
|
|
Environment | |
Operating Temperature Range |
40–140°F ambient
4–60°C ambient
|
Humidity Range |
0–95% non-condensing
0–95% non-condensing
|
Preset or Free-flow Limits | |
999.9 Units |
Maximum Preset or free-flow dispense
Maximum Preset or free-flow dispense
|
0.5 Units |
Minimum Preset dispense
Minimum Preset dispense
|
Dispense Units of Measure |
liters, quarts, gallons or pints (configurable for each fluid)
liters, quarts, gallons or pints (configurable for each fluid)
|
Inventory Units of Measure |
liters or gallons (dependent upon dispense units chosen)
liters or gallons (dependent upon dispense units chosen)
|
Maximum Cable Lengths | |
From Keypad to Control Module |
50 ft
15.3 m
|
From Solenoid to Control Module |
50 ft
15.3 m
|
From Pulse Meter to Control Module |
50 ft
15.3 m
|
From Printer or Computer to Master Control Module |
50 ft
15.3 m
|
From one end of the Control Module Network to the other end (daisy-chained) |
2000 ft
610 m
|