Work faster and smarter with Graco’s exclusive Data Management System (DMS™). Find out exactly how your lubrication system is performing and how well it’s lubricated. Tracks history, provides data protection, upload or download data using a simple USB flash drive.
G3 Max Automatic Lubrication for Series Progressive and Injector-Based Systems
Full Featured with DMS Option
Extend machinery life, reduce operating costs and increase productivity with a Graco G3 today!
G3’s flexible design works with injector-based and series progressive systems. A cost-effective pump designed to serve multiple markets and applications.
Three controllers to choose from with multiple zone and feedback options. Includes one adjustable pump element–standard, plus room for two more. Multiple reservoir choices and more! The ultimate in flexibility–for a high value, custom fit on your application.


- Built-in controller with selectable pump on/pump off timer
- Low level indicator provides low warning and shut-down alarm
- Manual run initiates lube cycle on-demand (remote option also available)
- Password protection safeguards
- Pre-lube function can initiate lube cycle on start-up
- Up to three pressure or cycle switch inputs to ensure proper lubrication cycles
- Mix/match cycle and pressure switches for custom installations and feedback
- Machine count input–ideally suited for inconsistently used equipment
- Fault indication to external alarms
- Optional Data Management System™ (DMS)
Vadovai
- 3A0526E G3 Vent Valve Kit, Instructions, English [kitos kalbos]
- 3A0525G G3/G1 Pressure Relief with Return to Reservoir Installation Kit [kitos kalbos]
- 3A0534K G3 Reservoir and O-Ring Replacment Kit, English [kitos kalbos]
- 3A0533D G3 Pump Element Replacement Kit, Instructions, English [kitos kalbos]
- 3A0528G G3 Illuminated Remote Run Kit [kitos kalbos]
- 3A0523G G3 Ouput Union Kit, Instructions, English [kitos kalbos]
- 199358ZBH, G1 , G3 and Automatic Lubrication Pump, EU-Declaration of Conformity (Tik anglų k.)
- 332305M, Manual, G3 Max Automatic Lubrication Pump, Instructions, English [kitos kalbos]
- 333488A G3 Lubrication Pump Food and Beverage Kit, Instructions, English (Tik anglų k.)
- 3A0522C G3 Pressure Relief Valve Adapter Kit, Instructions, English [kitos kalbos]
- 3A0535F, G3 Paddle Replacement Kit, Instructions, English [kitos kalbos]
- 333508M, Komatsu Wheel Loader Installation Instructions, English (Tik anglų k.)
- Komatsu HM300-5/HM400-5; 333510E (Tik anglų k.)
- 333514C, Komatsu PC210/PC240/PC290 and PC360/PC390/PC490 Excavator Installtion Instructions (Tik anglų k.)
3A0525G G3/G1 Pressure Relief with Return to Reservoir Installation Kit
332305M, Manual, G3 Max Automatic Lubrication Pump, Instructions, English
3A0522C G3 Pressure Relief Valve Adapter Kit, Instructions, English
Literatūra
- 300765ENEU Automatic lubrication [kitos kalbos]
- 340574ENEU G3 Electric Lubrication Pump [kitos kalbos]
- 340821ENEU-AD Automatic Lubrication Equipment Buyers Guide [kitos kalbos]
- Off-Road Mobile Kit Selection Guide (Tik anglų k.)
- Graco G3 Kit Form Solutions (Tik anglų k.)
- Graco G3 Pumps with Auto-Fill Shutoff Flyer (Tik anglų k.)
- 300737ENEU Marine Equipment [kitos kalbos]
- Graco Lubrication Solutions for Your Food or Beverage Business Brochure (Tik anglų k.)
- Graco Fracturing Equipment Selection Guide (Tik anglų k.)
G3 Automatic Lubrication Pump | |
Maximum Working Pressure | |
Maximum Working Pressure |
5100 psi
35.1 MPa/351.6 bar
|
Power | |
100–240 VAC |
88 - 264 VAC, 0.8 A current, 90 VA Power, 47/63 Hz, Single phase
88 - 264 VAC, 0.8 A current, 90 VA Power, 47/63 Hz, Single phase
|
12 VDC |
9 - 16 VDC, 5 A current, 60 W, inrush/locked rotor 12 A
9 - 16 VDC, 5 A current, 60 W, inrush/locked rotor 12 A
|
24 VDC |
18 - 32 VDC, 2.5 A current, 60 W, inrush/locked rotor 6 A
18 - 32 VDC, 2.5 A current, 60 W, inrush/locked rotor 6 A
|
Outputs — Alarm Relay | |
Rated Load |
Resistive: 0.4 A at 125 VAC, 2 A at 30 VDC, Inductive: 0.2 A at 125 VAC, 1 A at 30 VDC
Resistive: 0.4 A at 125 VAC, 2 A at 30 VDC, Inductive: 0.2 A at 125 VAC, 1 A at 30 VDC
|
Max Operating Voltage |
Resistive: 250 VAC, 220 VAC, Inductive: 250 VAC, 220 VDC
Resistive: 250 VAC, 220 VAC, Inductive: 250 VAC, 220 VDC
|
Max Operating Current |
Resistive: 3 A (AC), 3A (DC), Inductive: 1.5 A (AC), 1.5 A (DC)
Resistive: 3 A (AC), 3A (DC), Inductive: 1.5 A (AC), 1.5 A (DC)
|
Max Switching Capacity |
Resistive: 50 VA, 60 W, Inductive: 25 VA, 30 W
Resistive: 50 VA, 60 W, Inductive: 25 VA, 30 W
|
Min Permissible Load |
Resistive: 10 μA, 10m VDC, Inductive: 10 μA, 10m VDC
Resistive: 10 μA, 10m VDC, Inductive: 10 μA, 10m VDC
|
Outputs — Vent Valve | |
Required Vent Valve Type |
Normally Closed
Normally Closed
|
Output Voltage 100/240 VAC |
24 VDC
24 VDC
|
Output Voltage 12 VDC |
Input Voltage
Input Voltage
|
Output Voltage 24 VDC |
Input Voltage
Input Voltage
|
Max Operating Current |
2 A
2 A
|
Max Operating Power |
48 W
48 W
|
Outputs — Low Level (Dry Contact) | |
Contact Rating |
10 Watts Maximum
10 Watts Maximum
|
Switch Rating |
200 VDC Maximum
200 VDC Maximum
|
Switching Current |
0.5 A Maximum
0.5 A Maximum
|
Carry Current |
1.2 A Maximum
1.2 A Maximum
|
Inputs — Cycle Pressure, 1, 2, 3, Machine Count | |
Required Switch Type |
Normally open (sink, source, or dry contact)
Normally open (sink, source, or dry contact)
|
Sensor Voltage 100/240 VAC |
24 VDC
24 VDC
|
Sensor Voltage 12 VDC |
Input Voltage
Input Voltage
|
Sensor Voltage 24 VDC |
Input Voltage
Input Voltage
|
Load Current 100/240 VAC |
22mA @ 24 VDC
22mA @ 24 VDC
|
Load Current 12 VDC |
11mA @ 12 VDC
11mA @ 12 VDC
|
Load Current 24 VDC |
22mA @ 24 VDC
22mA @ 24 VDC
|
Maximum Residual Voltage 100/240 VAC |
4 V
4 V
|
Maximum Residual Voltage 12 VDC |
2 V
2 V
|
Maximum Residual Voltage 24 VDC |
4 V
4 V
|
Maximum Off Current 100/240 VAC |
1.5 mA
1.5 mA
|
Maximum Off Current 12 VDC |
1 mA
1 mA
|
Maximum Off Current 24 VDC |
1.5 mA
1.5 mA
|
Input Impedance |
1.1
1.1
|
Response Time |
60 ms
60 ms
|
Cycle Rate |
8.0 Hz (50% duty cycle)
8.0 Hz (50% duty cycle)
|
Fluid Grease Models |
Grease NLGI 000 — #2
Grease NLGI 000 — #2
|
Fluid Oil Models |
At least 40 cSt oil. Oil units with low level must have at least 80 cSt.
At least 40 cSt oil. Oil units with low level must have at least 80 cSt.
|
Pumps |
Up to 3
Up to 3
|
Pump Output – 2 spacers |
0.12 sq in (2 sq cm) / min per outlet - 2 spacer
0.12 sq in (2 sq cm) / min per outlet - 2 spacer
|
Pump Output – 1 spacer |
0.18 in 3 (3 cm3) / min per outlet - 1 spacer
0.18 in 3 (3 cm3) / min per outlet - 1 spacer
|
Pump Output – 0 spacers |
0.25 in 3 (4 cm3) / min per outlet - 0 spacers
0.25 in 3 (4 cm3) / min per outlet - 0 spacers
|
Pump Outlet |
1/4-18 NPSF. Mates with 1/4-18 NPT male fittings
1/4-18 NPSF. Mates with 1/4-18 NPT male fittings
|
Reservoir Size |
2 l
2 l
|
IP Rating |
IP69K
IP69K
|
Sensor Inputs |
3 (any of pressure or cycle)
3 (any of pressure or cycle)
|
Sensor Inputs |
1 (machine count)
1 (machine count)
|
Ambient Temps |
-13°F to 158°F
-25°C to 70°C
|
Weight (Dry - includes power cord and plug) Without follower plate |
13.3 lb
6.03 kg
|
Weight (Dry - includes power cord and plug) With Follower plate |
14.2 lb
6.44 kg
|
Wetted Parts |
nylon 6/6 (PA), trogamid T5004-060, zinc plated steel, carbon steel, alloy steel, stainless steel, nitrile rubber(buna-N), bronze, nickel plated alnico, chemically lubricated acetal, aluminum, PTFE, Grillamid
nylon 6/6 (PA), trogamid T5004-060, zinc plated steel, carbon steel, alloy steel, stainless steel, nitrile rubber(buna-N), bronze, nickel plated alnico, chemically lubricated acetal, aluminum, PTFE, Grillamid
|
Sound Data |
<60 dB
&lt;60 dB
|
-
Žemės ūkio įranga – techninė priežiūra
-
Statybinė įranga – techninė priežiūra
-
Vėjo energija – sutepimas
Esminių guolių taškų automatinio tepimo produktai
-
Cheminių medžiagų gamyba
-
Elektronikos gamyba
-
Baldų apdaila / gamyba
-
Prietaisų gamyba
-
Įrangos tepimo sistemų gamyba
-
Pradžioje: gręžimas ir užbaigimas
-
Pradžioje: gamybos įranga
-
Viduryje: vamzdynai ir suslėgimas
-
Spauda ir leidyba – įrangos tepimas
-
Vilkikai
-
Laivai
-
Atliekų tvarkymas – įrangos techninė priežiūra
-
Sunkioji technika – techninė priežiūra
-
Miškų įranga
-
Popieriaus gamyklos
-
Lentpjūvės
Susiję produktai
-
Air/Oil AO Series Valves
Detects air line or oil line faults in your system
-
Automatic Lubrication System Kits
Out-of-the-Box Lubrication Kits with Everything You Need for Installation
-
Automatic Relief Indicator
Keep your machine running while lubrication gets to critical points
-
Broken Line Indicator
Lubrication Accessory
-
Cycle Switch
Lubrication Accessories
-
G1 Plus
Built-in Controller
-
G1 Standard
Reliable entry level lubrication pump
-
G3 Pro
Built-in Controller
-
G3 Standard
Works with your PLC
-
GL-1 Series Grease Injectors
High volume output at high pressures for the most demanding applications
-
GL-32 Grease Injectors
Accurate, reliable lubrication for every lube point on your machine
-
GL-43 Oil Injectors
Accurate, reliable lubrication for every lube point on your machine
-
Magnetic Visual Cycle Indicator
-
Manual Hand Pump
Designed for filling grease reservoir
-
Manzel MHH Divider Valves
Series Progressive Metering Device
-
Pressure Switches
Lubrication Accessories
-
Proximity Switches
Lubrication Accessories
-
Reset Indicator
Easy information on blocked lines, high system pressure or blocked bearings
-
Rupture Indicator
Know quickly when critical bearings aren't getting lubricated
-
Trabon MD Divider Valve
Series Progressive Divider Valve
-
Trabon MJ Divider Valves
Compact and customizeable divider block series for machine tool, product or press equipment
-
Trabon MSP Divider Valves
Keeps machines running at peak performance
-
Trabon Spra-Control Valve
Lubrication Accessories
-
Trabon USP Divider Valve
Series Progressive Metering Device
-
Vent Valves
Industry leading feature for your lube system needs