- Reduced material waste
- No more throwing away unused mixed material at the end of the day
- Save money by using less clean-up solvent
- Consistent material quality - no more guesswork or human error in measuring materials
- Easy to operate - minimal training required
- Reduced maintenance costs
- Rated for 7250 psi (500 bar, 50 MPa) to handle viscous materials and long hose lengths
XP50 Quick-Set Packages Two-component spraying made easy and affordable
Optimized for quick-setting coatings
A smart alternative to hand mixing
Graco XP Plural-Component Sprayers are designed to pump, mix and atomize high-viscosity, high-solids coatings with superior results. When you upgrade from hand mixing, you'll find that the XP provides excellent return on investment, by reducing material waste and by using less clean-up solvent.
XP 50 Quick Set Packages
- Optimized for quick-setting hybrid and elastomeric urethane coatings
- Include a modified mix manifold (typically remove mounted) with fluid pressure gauges and solvent valves for both A and B materials, plus a shorter 10 ft static mix line to the spray gun. Heated hose is optional.
- Ideal replacement for Graco King Hydra-Cat™ quick-set packages
Try the ROI calculator in the Resources tab and see how much you can save.
Switch from hand-mixing and see the benefits

أدلة المستخدم
- 309524Z, Viscon HP High Pressure Fluid Heater, Instructions, Parts, English [اللغات الأخرى]
- 312145K, XTR 5 and XTR 7 Airless Spray Gun, Instructions, Parts, English [اللغات الأخرى]
- 3A0590P, Manual, Mix Manifold, Instructions, English [اللغات الأخرى]
- 3A0420ZAG, Manual, XP and XP-h Proportioners Operation, Repair, and Parts, English [اللغات الأخرى]
- 3A0421B, Manual, Ratio Check Kit, Instructions, English (الإنجليزية فقط)
- 309852E -Reactor Circulation and Return Tube Kits, English (الإنجليزية فقط)
- 310863R, Manual, Feed and Solvent Flush Kits, Instructions and Parts, English [اللغات الأخرى]
- 311762ZAL, Manual, Xtreme Lowers, Instructions-Parts, English [اللغات الأخرى]
- 311486E, Manual, DataTrak Conversion Kit, Instructions, English [اللغات الأخرى]
- 312794L, Manual, Merkur Pump Assembly, Instructions and Parts, English [اللغات الأخرى]
- 312769G, Feed Pump Kits, XM, XP70, Instructions, English (الإنجليزية فقط)
- 312747L - Double Wall Hopper, Instructions-Parts, English [اللغات الأخرى]
309524Z, Viscon HP High Pressure Fluid Heater, Instructions, Parts, English
312145K, XTR 5 and XTR 7 Airless Spray Gun, Instructions, Parts, English
3A0590P, Manual, Mix Manifold, Instructions, English
3A0420ZAG, Manual, XP and XP-h Proportioners Operation, Repair, and Parts, English
310863R, Manual, Feed and Solvent Flush Kits, Instructions and Parts, English
311762ZAL, Manual, Xtreme Lowers, Instructions-Parts, English
311486E, Manual, DataTrak Conversion Kit, Instructions, English
312794L, Manual, Merkur Pump Assembly, Instructions and Parts, English
الأدب
- 350210ENEU, XP [اللغات الأخرى]
- 348546EN, Graco XP Pressure Monitor Kit Flyer (الإنجليزية فقط)
- 349329ENEU, Parts & Accessories [اللغات الأخرى]
- 349706ENEU, Xtreme-Duty Agitator [اللغات الأخرى]
- 300738ENEU SHIP & RIG BUILDING [اللغات الأخرى]
349329ENEU, Parts & Accessories
349706ENEU, Xtreme-Duty Agitator
الموارد الأخرى
XP and XP-h Proportioners | |
Maximum Fluid Working Pressure | See Models section in instruction manual. See Models section in instruction manual. |
Maximum Air/Hydraulic Oil Working Pressure | See Models section in instruction manual. See Models section in instruction manual. |
Combined Fluid Output (cc/cycle) | See Models section in instruction manual. See Models section in instruction manual. |
Pressure Ratio | See Models section in instruction manual. See Models section in instruction manual. |
Fluid Flow at 40 cpm | See Models section in instruction manual. See Models section in instruction manual. |
Hydraulic Fluid Consumption (XP-h models only) | 0.2 gallons per cycle 0.76 liters per cycle |
Air inlet size | 3/4 npsm(f) 3/4 npsm(f) |
Maximum air pressure supply to the system | 175 psi 12 bar, 1 MPa |
Fluid pump inlets without hoppers | 1-1/4 in. npsm(m) 1-1/4 in. npsm(m) |
Fluid gauge manifold outlets | 1/2 in. npt(f) 1/2 in. npt(f) |
Fluid mix manifold inlets | 1/2 in. npt(f) ball valves 1/2 in. npt(f) ball valves |
Mix manifold material outlet | 1/2 in. npt(f) 1/2 in. npt(f) |
Maximum feed pressure from remote source | 250 psi 17 bar, 1.7 MPa |
Sound pressure | 86 dBA at 100 psi 7 bar, 0.7 MPa |
Sound power | 98 dBA at 100 psi 7 bar, 0.7 MPa |
Maximum Storage Time | 5 years (To maintain original performance, replace soft seals after 5 years of inactivity.) 5 years (To maintain original performance, replace soft seals after 5 years of inactivity.) |
Maximum Lifetime | Indefinite with recommended maintenance and periodic rebuilds for critical parts. Indefinite with recommended maintenance and periodic rebuilds for critical parts. |
Power Efficiency Factor (XP70) | 75 cu. ft compressed air/1 gallon sprayed material at 100 psi 2.12 m³ compressed air/1 liter sprayed material at 7 bar (0.7 MPa) |
Air consumption per 1 gallon (3.78 l) of flow | |
XP70 | 75 scfm at 100 psi/gpm (2.12 m³/min at 7 bar, 0.7 MPa) 75 scfm at 100 psi/gpm (2.12 m³/min at 7 bar, 0.7 MPa) |
XP50 | 60 scfm at 100 psi/gpm (1.7 m³/min at 7 bar, 0.7 MPa) 60 scfm at 100 psi/gpm (1.7 m³/min at 7 bar, 0.7 MPa) |
XP35 | 50 scfm at 100 psi/gpm (1.42 m³/min at 7 bar, 0.7 MPa) 50 scfm at 100 psi/gpm (1.42 m³/min at 7 bar, 0.7 MPa) |
Filtration | |
Air inlet filtration | 40-micron filter/separator included 40-micron filter/separator included |
XP pump outlets | 30 mesh 30 mesh |
XTR Spray Gun | 60 mesh 60 mesh |
Fluid Viscosity Range | |
Gravity feed with 7 gallon (26 liter) hoppers | 200 to 20,000 cps (pourable) 200 to 20,000 cps (pourable) |
Pressure feed | Any viscosity that will not require feed pressure more than 15% of outlet pressure Any viscosity that will not require feed pressure more than 15% of outlet pressure |
Environmental Rating (Indoor/outdoor) | |
Hazardous Areas | EX II 2 G c IIA T2, NOTE: XP-h pump packages (284xxx) are not Ex rated. EX II 2 G c IIA T2, NOTE: XP-h pump packages (284xxx) are not Ex rated. |
Ambient Temperature Range | |
Operating | 40-130°F 4-54°C |
Storage | 30-160°F -1-71°C |
Maximum Fluid Temperature | 160°F 71°C |
Wetted materials | |
Housings and manifolds | Carbon steel with electroless nickel plating Carbon steel with electroless nickel plating |
Miscellaneous parts | Plated carbon steel, stainless steels, carbide, acetal, UHM-WPE, nylon, PTFE solvent resistant plastics Plated carbon steel, stainless steels, carbide, acetal, UHM-WPE, nylon, PTFE solvent resistant plastics |
Pump packings | Carbon filled PTFE, proprietary UHMWPE Carbon filled PTFE, proprietary UHMWPE |
Flush pump suction tube | Aluminum Aluminum |
Hoses | Nylon core Nylon core |
Weight | |
Full XP35, XP50, or XP70 System with heaters, solvent flush pump, and hoppers | 575 lb 261 kg |
Full XP-h System with heaters, solvent flush pump, and hoppers | 600 lb 273 kg |
Bare XP35, XP50, or XP70 system with no heaters, solvent flush pump, or hoppers | 425 lb 193 kg |
Bare XP-h System with no heaters, solvent flush pump, or hoppers | 450 lb 204 kg |
XP35, XP50, or XP70 Pump only | 286 lb 130 kg |
XP-h Pump only | 290 lb 132 kg |
-
مواد طلاء الأسقف
-
العزل ضد الصدأ
-
بناء السفن وأساطيل الشحن
-
الدهانات الواقية للجسور
-
تصنيع عربات السكك الحديدية وإصلاحها
-
Towers for Wind Turbines
-
دهان الأنابيب والخزانات
-
دهان حديد التسليح
-
الدهانات الواقية للأبراج المائية
-
معالجة الفضلات السائلة
-
ترميم فتحات الدخول للمجارير والمجارير
-
المنع الثانوي للتسرب بالاحتواء
-
السيطرة على التآكل
-
حفارات بحرية
مُلحقات
-
Gun Splitter
Lets you use two spray guns with one XP Sprayer
-
T1, T2 and T3 Transfer Pumps
Ideal for moving A and B materials to Reactor spray machines
-
Viscon Fluid Heaters
Provides excellent temperature conditioning for high solids coatings and high viscosity materials
-
XTR-5 and XTR-7
Airless spray guns for protective coatings
-
Xtreme-Duty Hose
For high-pressure spraying applications