G3 Max

G3™ Max Grease Pump, 90-240 VAC, 16L, Low Level with Controller, 3 Sensors, DIN, Machine Count, Vent Valve, Alarm, Remote Manual Run

Part Number: 96G121

product image product image
Image is for illustrative purposes only.
Image is for illustrative purposes only.

G3 Max

G3™ Max Grease Pump, 90-240 VAC, 16L, Low Level with Controller, 3 Sensors, DIN, Machine Count, Vent Valve, Alarm, Remote Manual Run

Part Number: 96G121

Extend machinery life, reduce operating costs and increase productivity with a Graco G3 today! The G3 Max has a flexible design that works with injector-based and series progressive systems. A cost-effective pump designed to serve multiple markets and applications. Includes one adjustable pump eleme...

More Info
Questions About this Product?

If you’re not finding the information you need, ask one of our experts.

Ask an Expert

Features

Product Brochure

Extend machinery life, reduce operating costs and increase productivity with a Graco G3 today! The G3 Max has a flexible design that works with injector-based and series progressive systems. A cost-effective pump designed to serve multiple markets and applications. Includes one adjustable pump element - standard, plus room for two more. The ultimate in flexibility - for a high value, custom fit on your application.

  • Built-in controller with selectable pump on/pump off timer
  • Low level indicator provides low warning and shut-down alarm
  • Manual run initiates lube cycle on-demand (remote option also available)
  • Password protection safeguards settings
  • Pre-lube function can initiate lube cycle on start-up
  • Up to three pressure or cycle switch inputs to ensure proper lubrication cycles
  • Mix/match cycle and pressure switches for custom installations and feedback
  • Machine count input - ideally suited for inconsistently used equipment
  • Fault indication to external alarms
  • Optional Data Management System (DMS)

    • Work faster and smarter with Graco's exclusive Data Management System (DMS)
    • Find out exactly how your lubrication system is performing and how well it's lubricated
    • Tracks history, provides data protection, upload or download data using a simple USB flash drive.

Specifications & Documents

Technical Specifications

Convert to Metric
Alarm Relay Inductive Maximum Operating Current (A) 1.5
Alarm Relay Inductive Maximum Operating Voltage (VAC) 250
Alarm Relay Inductive Maximum Switching Capacity 25 VA;30 W
Alarm Relay Inductive Rated Load (A) 0.2
Alarm Relay Resistive Maximum Operating Current (A) 3
Alarm Relay Resistive Maximum Operating Voltage (VAC) 250
Alarm Relay Resistive Maximum Switching Capacity 50 VA;60 W
Alarm Relay Resistive Minimum Permissible Load 10 µA;10m VDC
Alarm Relay Resistive Rated Load (A) 0.4
Application On-Road Vehicles, Off-Road Equipment
Compatible Material Grease
Compatible Metering Device Series Progressive, Single Line Parallel
Control Options Max
Fluid Outlet Size (in) 0.25
Fluid Outlet Thread Gender Female
Fluid Outlet Thread Type NPSF
For Use With Injector-Based Systems, Series Progressive Systems
IP Rating IP69K
Includes Machine Count, Vent Valve, DIN Alarm Output, M12 Connection for Remote, Wiper Arm, Low Level
Input Cycle Rate (Hz) 8
Input Impedance 1.1
Input Load Current (mA @ 24 VDC) 22
Input Maximum Off Current (mA) 1.5
Input Maximum Residual Voltage (V) 4
Input Required Switch Type Normally Open
Input Response Time (ms) 60
Input Sensor Voltage (VDC) 24
Low Level Carry Current (A) 1.2
Low Level Switching Current (A) 0.5
Maximum Fill Inlet Pressure (psi) 5000
Maximum NLGI Grade #2
Maximum Run Time (min) 30
Maximum Voltage (V ac) 264
Maximum Working Pressure (MPa) 35.1
Maximum Working Pressure (psi) 5100
Minimum Voltage (V ac) 88
Model G3
Number of Machine Count Sensor Inputs 1
Number of Pressure and Cycle Sensor Inputs 3
Number of Pump Elements Up to 3
Number of Sensor Inputs 3, 1
Overall Depth (in) 10
Overall Height (in) 27.5
Overall Width (in) 9.25
Power Connection Type DIN
Power Type Electric
Pump Output with 0 Spacers (cu in/min) 0.25
Pump Output with 1 Spacer (cu in/min) 0.18
Pump Output with 2 Spacers (cu in/min) 0.12
Reservoir Size (L) 16
Reservoir Size (gal) 4.23
Series Max
Type Electric Piston Pump
Vent Valve Maximum Operating Current (A) 2
Vent Valve Maximum Operating Power (W) 48
Vent Valve Output Voltage (VDC) 24
Voltage (V ac) 90-240
Voltage (V) 90-240 VAC
Weight (lb) 13.3
Alarm Relay Inductive Maximum Operating Current (A) 1.5
Alarm Relay Inductive Maximum Operating Voltage (VAC) 250
Alarm Relay Inductive Maximum Switching Capacity 25 VA;30 W
Alarm Relay Inductive Rated Load (A) 0.2
Alarm Relay Resistive Maximum Operating Current (A) 3
Alarm Relay Resistive Maximum Operating Voltage (VAC) 250
Alarm Relay Resistive Maximum Switching Capacity 50 VA;60 W
Alarm Relay Resistive Minimum Permissible Load 10 µA;10m VDC
Alarm Relay Resistive Rated Load (A) 0.4
Application On-Road Vehicles, Off-Road Equipment
Compatible Material Grease
Compatible Metering Device Series Progressive, Single Line Parallel
Control Options Max
Fluid Outlet Size (in) 0.25
Fluid Outlet Size (mm) 6.3500
Fluid Outlet Thread Gender Female
Fluid Outlet Thread Type NPSF
For Use With Injector-Based Systems, Series Progressive Systems
IP Rating IP69K
Includes Machine Count, Vent Valve, DIN Alarm Output, M12 Connection for Remote, Wiper Arm, Low Level
Input Cycle Rate (Hz) 8
Input Impedance 1.1
Input Load Current (mA @ 24 VDC) 22
Input Maximum Off Current (mA) 1.5
Input Maximum Residual Voltage (V) 4
Input Required Switch Type Normally Open
Input Response Time (ms) 60
Input Sensor Voltage (VDC) 24
Low Level Carry Current (A) 1.2
Low Level Switching Current (A) 0.5
Maximum Fill Inlet Pressure (bar) 344.7
Maximum Fill Inlet Pressure (kPa) 34470
Maximum Fill Inlet Pressure (psi) 5000
Maximum NLGI Grade #2
Maximum Run Time (min) 30
Maximum Voltage (V ac) 264
Maximum Working Pressure (MPa) 35.1
Maximum Working Pressure (bar) 351.6
Maximum Working Pressure (kPa) 35160
Maximum Working Pressure (psi) 5100
Minimum Voltage (V ac) 88
Model G3
Number of Machine Count Sensor Inputs 1
Number of Pressure and Cycle Sensor Inputs 3
Number of Pump Elements Up to 3
Number of Sensor Inputs 3, 1
Overall Depth (cm) 25.4
Overall Depth (mm) 254
Overall Height (cm) 69.9
Overall Height (mm) 699
Overall Width (cm) 23.5
Overall Width (mm) 235
Power Connection Type DIN
Power Type Electric
Reservoir Size (L) 16
Series Max
Type Electric Piston Pump
Vent Valve Maximum Operating Current (A) 2
Vent Valve Maximum Operating Power (W) 48
Vent Valve Output Voltage (VDC) 24
Voltage (V ac) 90-240
Voltage (V) 90-240 VAC
Weight (kg) 6

GET HELP FROM A LOCAL DEALER

Showing dealers for

Have Questions? Let's Talk.

Call Support

Call Support

Monday–Friday
7:30 a.m.–5 p.m. Central Time

Email Support

Email Support

Contact Graco

Contact Graco

We'll help you choose the right product for your use.

Reviews

Graco