Ask an ExpertFeatures
Product BrochureThis groundbreaking electric pump is designed with a polyvinylidene fluoride (PVDF) fluid section that provides high corrosion and abrasion resistance to a variety of aggressive fluids and solvents. It efficiently handles fluid transfer applications involving highly concentrated chemicals or detergents, sump evacuation applications, as well as those involving high and low pH materials. With up to 8x more continuous torque at low speeds than conventional motors, this powerful new pump delivers a higher level of reliability to minimize downtime while the plug-and-play design makes it easy to drop into any production line without additional investment or infrastructure rework.
- Revolutionary Design
- Replace existing air operated pumps with electric pump technology that stalls under pressure and includes AutoPrime feature
- Compact and efficient electric drive removes the gearbox providing a comparable footprint to a pneumatic diaphragm pump
- Up to 80% reduction in energy consumption compared to pneumatic pumps, reducing operating costs and providing a quick investment payback
- Quiet operation reduces plant noise and improves employee safety and health
- Smart pump control provides more accurate flow set points and built-in I/O
- Efficient Electric Motor
- Powder-coated aluminum electric drive
- 120 VAC 1φ motor with 15 ft cord and NEMA 5-15 plug
- Non-hazardous
- Materials of Construction
- PVDF (Kynar) fluid section with end flange
- Internal components include PVDF (Kynar) seat, 316 stainless steel ball, PTFE/Santoprene 2-piece diaphragm and PTFE manifold o-ring
Specifications & Documents
Technical Specifications
Convert to MetricApplication | Chemical Processing, Paints and Coatings, Waste Water, General Fluid Transfer |
---|---|
Ball Material | 316 Stainless Steel |
Center Section Material | Aluminum |
Configuration Code | QTC-PVFC5PVSSPSPTF200 |
Connection Type | Flange |
Construction | PVDF (Kynar), 316 Stainless Steel, PTFE/Santoprene 2-Piece, PTFE |
Cord Length (ft) | 15 |
Diaphragm Material | PTFE/Santoprene 2-Piece |
Fluid Inlet Size (in) | 1 |
Fluid Inlet Thread Gender | Flange |
Fluid Inlet Thread Type | Flange |
Fluid Outlet Size (in) | 1 |
Fluid Outlet Thread Gender | Flange |
Fluid Outlet Thread Type | Flange |
Fluid Passage Size (in) | 1 |
Fluid Passage Size (mm) | 25 |
Fluid Section | PVDF (Kynar), End Flange |
Fluid Section Material | PVDF (Kynar) |
Hazardous Location Approval | None |
Manifold Configuration | End Flange |
Manifold O-Ring Material | PTFE |
Maximum Ambient Temperature (°F) | 104 |
Maximum Amperage (A) | 12 |
Maximum Flow Rate (GPM) | 30 |
Maximum Fluid Operating Temperature (°C) | 82 |
Maximum Fluid Operating Temperature (°F) | 180 |
Maximum Fluid Pressure (psi) | 100 |
Maximum Solid Size (in) | 0.125 |
Minimum Fluid Operating Temperature (°C) | -12 |
Minimum Fluid Operating Temperature (°F) | 10 |
Model | QUANTM |
Motor Type | Electric Drive |
Overall Height (in) | 17.8 |
Seat Material | PVDF (Kynar) |
Series | i30 |
Type | Electric Diaphragm Pump |
Voltage (V ac) | 100-120 VAC 1Ph |
Weight (lb) | 67 |
Application | Chemical Processing, Paints and Coatings, Waste Water, General Fluid Transfer |
Ball Material | 316 Stainless Steel |
Center Section Material | Aluminum |
Configuration Code | QTC-PVFC5PVSSPSPTF200 |
Connection Type | Flange |
Construction | PVDF (Kynar), 316 Stainless Steel, PTFE/Santoprene 2-Piece, PTFE |
Cord Length (m) | 4.57 |
Diaphragm Material | PTFE/Santoprene 2-Piece |
Fluid Inlet Size (in) | 1 |
Fluid Inlet Size (mm) | 25.4 |
Fluid Inlet Thread Gender | Flange |
Fluid Inlet Thread Type | Flange |
Fluid Outlet Size (in) | 1 |
Fluid Outlet Size (mm) | 25.4 |
Fluid Outlet Thread Gender | Flange |
Fluid Outlet Thread Type | Flange |
Fluid Passage Size (in) | 1 |
Fluid Passage Size (mm) | 25 |
Fluid Section | PVDF (Kynar), End Flange |
Fluid Section Material | PVDF (Kynar) |
Hazardous Location Approval | None |
Manifold Configuration | End Flange |
Manifold O-Ring Material | PTFE |
Maximum Ambient Temperature (°C) | 40 |
Maximum Amperage (A) | 12 |
Maximum Flow Rate (L/min) | 114 |
Maximum Fluid Operating Temperature (°C) | 82 |
Maximum Fluid Operating Temperature (°F) | 180 |
Maximum Fluid Pressure (bar) | 6.9 |
Maximum Fluid Pressure (kPa) | 690 |
Maximum Fluid Pressure (psi) | 100 |
Maximum Solid Size (mm) | 3.2 |
Minimum Fluid Operating Temperature (°C) | -12 |
Minimum Fluid Operating Temperature (°F) | 10 |
Model | QUANTM |
Motor Type | Electric Drive |
Seat Material | PVDF (Kynar) |
Series | i30 |
Type | Electric Diaphragm Pump |
Voltage (V ac) | 100-120 VAC 1Ph |
Product Manuals
Sales Literature
Certifications
Repair Parts
Part No. | Description |
---|---|
2003771 | QUANTM i130 Complete Fluid Repair Kit with PV Seat, SS Ball, PS Diaphragm and PT Seal |
24C721 | 1-inch PVDF Seat Kit |
24F926 | PTFE/Santoprene 2-Piece Diaphragm Kit for 1-inch Pump |
D07030 | 1-inch 316 Stainless Steel Check Ball Kit |
24B655 | 1-inch PTFE Seal Kit |
25F122 | QUANTM i/h30 Rotor Kit |
25F102 | QUANTM i-Series Pump Control Knob for Ordinary Location Industrial Pump Models |
25V129 | QUANTM i30 Stator Cap Kit |
19B741 | Power Cord for Ordinary Location F-5 Motor 1-inch QUNATM Pumps |