- Allows multiple technicians to dispense simultaneously
- Easily configured and expandable for any facility
- Increases technician productivity
- Password-protected to prevent unauthorized dispensing
- Tracks inventory levels and alerts operators to low inventory conditions to minimize out-of-stock situations
Horizon Fluid Management Systems Electronic Fluid Management System
Bulk dispensing to multiple service bays

Bruksanvisningar
- 308607J Horizon Fluid Management System, Instructions, English (Endast på engelska)
Trycksaker
Horizon | |
System Specifications | |
40 maximum |
Control Modules in a system (1 Master only, plus 39 Slave)
Control Modules in a system (1 Master only, plus 39 Slave)
|
40 maximum |
Keypads in a system (1 keypad per Control Module; Administrators Keypad must be connected to the Master Control Module)
Keypads in a system (1 keypad per Control Module; Administrators Keypad must be connected to the Master Control Module)
|
240 maximum |
Solenoids in a system (40 Control Modules, 6 ports each)
Solenoids in a system (40 Control Modules, 6 ports each)
|
240 maximum |
Meters in a system (40 Control Modules, 6 ports each)
Meters in a system (40 Control Modules, 6 ports each)
|
10 maximum |
Fluids supported by a system
Fluids supported by a system
|
99 maximum |
Dispense Areas (reel banks)
Dispense Areas (reel banks)
|
100 maximum |
Operator Names/PIN numbers
Operator Names/PIN numbers
|
668 maximum |
Dispense Records stored
Dispense Records stored
|
12 maximum |
Simultaneous Dispenses (same and/or different fluids)
Simultaneous Dispenses (same and/or different fluids)
|
12 maximum |
Jobs Waiting in Queue
Jobs Waiting in Queue
|
1 maximum |
Printer per system (must be connected to Master Control Module) OR Attached Computer per system (must be connected to Master Control Module)
Printer per system (must be connected to Master Control Module) OR Attached Computer per system (must be connected to Master Control Module)
|
Control Module Ports | |
6 |
Solenoid Ports per Control Module
Solenoid Ports per Control Module
|
6 |
Pulse Meter Ports per Control Module
Pulse Meter Ports per Control Module
|
1 |
Port for Keypad per Control Module
Port for Keypad per Control Module
|
1 |
Port for printer or computer per Master Control Module
Port for printer or computer per Master Control Module
|
1 |
Bar code reader per control module
Bar code reader per control module
|
Voltage Input | |
110 Volts AC, 50/60 Hz, 2 amps maximum draw
110 Volts AC, 50/60 Hz, 2 amps maximum draw
|
|
220 Volts AC, 50/60 Hz, 1 amp maximum draw
220 Volts AC, 50/60 Hz, 1 amp maximum draw
|
|
Environment | |
Operating Temperature Range |
40–140°F ambient
4–60°C ambient
|
Humidity Range |
0–95% non-condensing
0–95% non-condensing
|
Preset or Free-flow Limits | |
999.9 Units |
Maximum Preset or free-flow dispense
Maximum Preset or free-flow dispense
|
0.5 Units |
Minimum Preset dispense
Minimum Preset dispense
|
Dispense Units of Measure |
liters, quarts, gallons or pints (configurable for each fluid)
liters, quarts, gallons or pints (configurable for each fluid)
|
Inventory Units of Measure |
liters or gallons (dependent upon dispense units chosen)
liters or gallons (dependent upon dispense units chosen)
|
Maximum Cable Lengths | |
From Keypad to Control Module |
50 ft
15.3 m
|
From Solenoid to Control Module |
50 ft
15.3 m
|
From Pulse Meter to Control Module |
50 ft
15.3 m
|
From Printer or Computer to Master Control Module |
50 ft
15.3 m
|
From one end of the Control Module Network to the other end (daisy-chained) |
2000 ft
610 m
|
-
Smörjning
Utrustning för service och underhåll av fordon och maskiner som förlänger deras livslängd och gör att de fun...
-
Överföring av kemikalier
Överföringspumpar och utmatningsutrustning för kemikalier
-
Överföring av olja
Överföringspumpar och utmatningsutrustning för olja
-
Fluid Management
Discover the relevance of bulk oil and fluid inventory control for service shops and industrial appli...