GLC 2200 Controller Compact and Versatile Controller for Automatic Lubrication Systems
The GLC 2200 is a workhorse designed with user-friendly features you can really use. Visual and audible alarms ensure your equipment is lubricated properly.
Make smarter decisions about how you control your equipment. Choose the rugged GLC 2200 controller for in-cab monitoring of any 9-30 VDC system.
- Programmable Pin Code Lock-Out keeps lubrication settings safe.
- External Mounting Tabs make it easy to mount without having to open up the control box.
- Monitoring LEDs let you know what your system is doing at a glance.
- Easy to read digital display makes it simple to program and monitor your equipment.
- In-cab visual and audible alarms lets the operator know your equipment needs attention. Or set up a remote audible alarm to alert service or maintenance staff.
- Color coded wiring harness with flying leads and easy to follow wiring diagrams makes installations efficient.
- Protection Grade IP54.
Priručnici
- 3A2960G, Manual, GLC 2200 Lubrication Controller, Instructions, English [drugi jezici]
- 3A2992B, GLC2200 Wiring Connector Kit, Instructions, English (Samo engleski)
- GLC2200 Wiring Harness Kit 3A2993C (Samo engleski)
- 199444F, GLC 2200, GJ CONTROL, 318-162 EC-Declaration of Conformity (European Community) (Samo engleski)
Literatura
- 300763ENEU Automatic Lubrication [drugi jezici]
- 340969ENEU_GLC 2200 Controller [drugi jezici]
- 340821ENEU-AD Automatic Lubrication Equipment Buyers Guide [drugi jezici]
- 300737ENEU Marine Equipment [drugi jezici]
340821ENEU-AD Automatic Lubrication Equipment Buyers Guide
GLC 2200 Lubrication Controller | |
U.S.
Metric
|
|
Input Contact: | |
Power Source DC |
9 - 30 VDC
9 - 30 VDC
|
Power Consumption |
1 Watt
1 Watt
|
Cycle/Pressure Control Input (optional) |
9 - 30 VDC, Normally open Pressure or cycle switch
9 - 30 VDC, Normally open Pressure or cycle switch
|
Lubrication level (optional) |
Normally open level switch, closes upon low level
Normally open level switch, closes upon low level
|
Outputs: | |
Pump control |
Pump Control Voltage = Power Source
Pump Control Voltage = Power Source
|
Voltage |
Pump Control Voltage = Power Source
Pump Control Voltage = Power Source
|
Max Switching Voltage |
30 VDC
30 VDC
|
Max Switching Current |
9A (DC)
9A (DC)
|
Min Switching Current |
100 mA (DC)
100 mA (DC)
|
Alarm, normally open | |
Voltage |
Alarm = Power Source
Alarm = Power Source
|
Max Switching Voltage |
30 VDC
30 VDC
|
Max Switching Current |
9A (DC)
9A (DC)
|
Protection grade |
IP54 for indoors and vehicle cab use
IP54 for indoors and vehicle cab use
|
Alarm Sound Pressure Level |
75 dB
75 dB
|
Enclosure Material |
ABS
ABS
|
Membrane Material |
Polyester
Polyester
|
Maximum Humidity |
90% RH (non-condensing)
90% RH (non-condensing)
|
Operating temperature range |
- 40°F to 176°F
(- 40°C to 80°C)
|
Storage Temperature |
- 40°F to 176°F
(- 40°C to 80°C)
|