G3 Max
G3™ Max Oil Pump, 90-240 VAC, 8 Litre, LL w/ Control, USB, DIN, 2 Sensors, Mach Count, Vent Valve, Alarm, Rem Man Run
Part Number: 96G176
G3 Max
G3™ Max Oil Pump, 90-240 VAC, 8 Litre, LL w/ Control, USB, DIN, 2 Sensors, Mach Count, Vent Valve, Alarm, Rem Man Run
Part Number: 96G176
Extend machinery life, reduce operating costs and increase productivity with a Graco G3 today! The G3 Max has a flexible design that works with injector-based and series progressive systems. A cost-effective pump designed to serve multiple markets and applications. Includes one adjustable pump eleme...
More InfoFeatures
Product BrochureExtend machinery life, reduce operating costs and increase productivity with a Graco G3 today! The G3 Max has a flexible design that works with injector-based and series progressive systems. A cost-effective pump designed to serve multiple markets and applications. Includes one adjustable pump element - standard, plus room for two more. The ultimate in flexibility - for a high value, custom fit on your application.
- Built-in controller with selectable pump on/pump off timer
- Low level indicator provides low warning and shut-down alarm
- Manual run initiates lube cycle on-demand (remote option also available)
- Password protection safeguards settings
- Pre-lube function can initiate lube cycle on start-up
- Up to three pressure or cycle switch inputs to ensure proper lubrication cycles
- Mix/match cycle and pressure switches for custom installations and feedback
- Machine count input - ideally suited for inconsistently used equipment
- Fault indication to external alarms
Optional Data Management System (DMS)
- Work faster and smarter with Graco's exclusive Data Management System (DMS)
- Find out exactly how your lubrication system is performing and how well it's lubricated
- Tracks history, provides data protection, upload or download data using a simple USB flash drive.
Specifications & Documents
Technical Specifications
Convert to Imperial| Alarm Relay Inductive Maximum Operating Current (A) | 1.5 |
|---|---|
| Alarm Relay Inductive Maximum Switching Capacity | 25 VA;30 W |
| Alarm Relay Inductive Minimum Permissible Load | 10 ?A;10m VDC |
| Alarm Relay Inductive Rated Load (A) | 0.2 |
| Alarm Relay Resistive Maximum Operating Current (A) | 3 |
| Alarm Relay Resistive Maximum Switching Capacity | 50 VA;60 W |
| Alarm Relay Resistive Minimum Permissible Load | 10 µA;10m VDC |
| Alarm Relay Resistive Rated Load (A) | 0.4 |
| Alarm relay inductive maximum operating voltage (VAC) | 250 |
| Alarm relay resistive maximum operating voltage (VAC) | 250 |
| Application | On-Road Vehicles, Off-Road Equipment |
| Cellular connectivity | No |
| Compatible Material | Oil |
| Compatible Metering Device | Series Progressive, Single Line Parallel |
| Control Options | Max |
| Fluid Outlet Size (in) | 0.25 |
| Fluid Outlet Thread Gender | Female |
| Fluid Outlet Thread Type | NPSF |
| For Use With | Injector-Based Systems, Series Progressive Systems |
| IP Rating | IP69K |
| Includes | Machine Count, Vent Valve, DIN Alarm Output, M12 Connection for Remote, Wiper Arm, Low Level |
| Input Cycle Rate (Hz) | 8 |
| Input Impedance | 1.1 |
| Input Required Switch Type | Normally open |
| Input maximum Off current (mA) | 1.5 |
| Input response time (ms) | 60 |
| Input sensor voltage (VDC) | 24 |
| Low Level Carry Current (A) | 1.2 |
| Low Level Contact Rating (W) | 10 |
| Low Level Switching Current (A) | 0.5 |
| Low level switch rating (VDC) | 200 |
| Maximum Fill Inlet Pressure (psi) | 5000 |
| Maximum NLGI Grade | #2 |
| Maximum Run Time (min) | 30 |
| Maximum Voltage (V ac) | 264 |
| Maximum Working Pressure (MPa) | 35.1 |
| Maximum Working Pressure (psi) | 5100 |
| Minimum Voltage (V ac) | 88 |
| Model | G3 |
| Number of Machine Count Sensor Inputs | 1 |
| Number of Pressure and Cycle Sensor Inputs | 3 |
| Number of Pump Elements | Up to 3 |
| Number of Sensor Inputs | 3, 1 |
| Overall Depth (in) | 10 |
| Overall Height (in) | 18.5 |
| Overall Width (in) | 9.25 |
| Power Connection Type | DIN |
| Power Type | Electric |
| Pump Output with 0 Spacers (cu in/min) | 0.25 |
| Pump Output with 1 Spacer (cu in/min) | 0.18 |
| Reservoir Size (L) | 8 |
| Reservoir Size (gal) | 2.11 |
| Series | Max |
| Type | Electric Piston Pump |
| Vent Valve Maximum Operating Current (A) | 2 |
| Vent Valve Maximum Operating Power (W) | 48 |
| Vent valve output voltage (VDC) | 24 |
| Voltage (V ac) | 90-240 |
| Voltage (V) | 90-240 VAC |
| Weight (lb) | 13.3 |
| Wetted Material | Nylon, Trogamid T5004-060, Zinc-Plated Steel, Carbon Steel, Alloy Steel, Stainless Steel, Nitrile Rubber, Bronze, Nickel-Plated Alnico, Chemically Lubricated Acetal, Aluminium, PTFE, Grilamid |
| Alarm Relay Inductive Maximum Operating Current (A) | 1.5 |
| Alarm Relay Inductive Maximum Switching Capacity | 25 VA;30 W |
| Alarm Relay Inductive Minimum Permissible Load | 10 ?A;10m VDC |
| Alarm Relay Inductive Rated Load (A) | 0.2 |
| Alarm Relay Resistive Maximum Operating Current (A) | 3 |
| Alarm Relay Resistive Maximum Switching Capacity | 50 VA;60 W |
| Alarm Relay Resistive Minimum Permissible Load | 10 µA;10m VDC |
| Alarm Relay Resistive Rated Load (A) | 0.4 |
| Alarm relay inductive maximum operating voltage (VAC) | 250 |
| Alarm relay resistive maximum operating voltage (VAC) | 250 |
| Application | On-Road Vehicles, Off-Road Equipment |
| Cellular connectivity | No |
| Compatible Material | Oil |
| Compatible Metering Device | Series Progressive, Single Line Parallel |
| Control Options | Max |
| Fluid Outlet Size (in) | 0.25 |
| Fluid Outlet Size (mm) | 6.3500 |
| Fluid Outlet Thread Gender | Female |
| Fluid Outlet Thread Type | NPSF |
| For Use With | Injector-Based Systems, Series Progressive Systems |
| IP Rating | IP69K |
| Includes | Machine Count, Vent Valve, DIN Alarm Output, M12 Connection for Remote, Wiper Arm, Low Level |
| Input Cycle Rate (Hz) | 8 |
| Input Impedance | 1.1 |
| Input Required Switch Type | Normally open |
| Input maximum Off current (mA) | 1.5 |
| Input response time (ms) | 60 |
| Input sensor voltage (VDC) | 24 |
| Low Level Carry Current (A) | 1.2 |
| Low Level Contact Rating (W) | 10 |
| Low Level Switching Current (A) | 0.5 |
| Low level switch rating (VDC) | 200 |
| Maximum Fill Inlet Pressure (bar) | 344.7 |
| Maximum Fill Inlet Pressure (kPa) | 34470 |
| Maximum Fill Inlet Pressure (psi) | 5000 |
| Maximum NLGI Grade | #2 |
| Maximum Run Time (min) | 30 |
| Maximum Voltage (V ac) | 264 |
| Maximum Working Pressure (MPa) | 35.1 |
| Maximum Working Pressure (bar) | 351.6 |
| Maximum Working Pressure (kPa) | 35160 |
| Minimum Voltage (V ac) | 88 |
| Model | G3 |
| Number of Machine Count Sensor Inputs | 1 |
| Number of Pressure and Cycle Sensor Inputs | 3 |
| Number of Pump Elements | Up to 3 |
| Number of Sensor Inputs | 3, 1 |
| Overall Depth (cm) | 25.4 |
| Overall Depth (mm) | 254 |
| Overall Height (cm) | 47 |
| Overall Height (mm) | 470 |
| Overall Width (cm) | 23.5 |
| Overall Width (mm) | 235 |
| Power Connection Type | DIN |
| Power Type | Electric |
| Reservoir Size (L) | 8 |
| Series | Max |
| Type | Electric Piston Pump |
| Vent Valve Maximum Operating Current (A) | 2 |
| Vent Valve Maximum Operating Power (W) | 48 |
| Vent valve output voltage (VDC) | 24 |
| Voltage (V ac) | 90-240 |
| Voltage (V) | 90-240 VAC |
| Weight (kg) | 6 |
| Wetted Material | Nylon, Trogamid T5004-060, Zinc-Plated Steel, Carbon Steel, Alloy Steel, Stainless Steel, Nitrile Rubber, Bronze, Nickel-Plated Alnico, Chemically Lubricated Acetal, Aluminium, PTFE, Grilamid |