Graco Inc.

XP50 Plural-Component Sprayer  Two-component spraying made easy and affordable

For higher-volume protective coatings

Kust ostaTeabepäring

A smart alternative to hand mixing

Graco XP Plural-Component Sprayers are designed to pump, mix and atomize high-viscosity, high-solids coatings with superior results. When you upgrade from hand mixing, you'll find that the XP provides excellent return on investment, by reducing material waste and by using less clean-up solvent.

Engineered for more flow capacity, the Graco XP50 is great for applications where you want to spray with multiple guns or larger tip sizes. The XP50 provides more production, so you can get the job done faster.

Try the ROI calculator in the Resources tab and see how much you can save.

Switch from hand-mixing and see the benefits

XP50 protective coatings application 4
  • Reduced material waste 
  • No more throwing away unused mixed material at the end of the day
  • Save money by using less clean-up solvent
  • Consistent material quality - no more guesswork or human error in measuring materials
  • Easy to operate - minimal training required
  • Reduced maintenance costs
  • Rated for 7250 psi (500 bar, 50 MPa) to handle viscous materials and long hose lengths

Juhendid



XP and XP-h Proportioners
Maximum Fluid Working Pressure
See Models section in instruction manual.
See Models section in instruction manual.
Maximum Air/Hydraulic Oil Working Pressure
See Models section in instruction manual.
See Models section in instruction manual.
Combined Fluid Output (cc/cycle)
See Models section in instruction manual.
See Models section in instruction manual.
Pressure Ratio
See Models section in instruction manual.
See Models section in instruction manual.
Fluid Flow at 40 cpm
See Models section in instruction manual.
See Models section in instruction manual.
Hydraulic Fluid Consumption (XP-h models only)
0.2 gallons per cycle
0.76 liters per cycle
Air inlet size
3/4 npsm(f)
3/4 npsm(f)
Maximum air pressure supply to the system
175 psi
12 bar, 1 MPa
Fluid pump inlets without hoppers
1-1/4 in. npsm(m)
1-1/4 in. npsm(m)
Fluid gauge manifold outlets
1/2 in. npt(f)
1/2 in. npt(f)
Fluid mix manifold inlets
1/2 in. npt(f) ball valves
1/2 in. npt(f) ball valves
Mix manifold material outlet
1/2 in. npt(f)
1/2 in. npt(f)
Maximum feed pressure from remote source
250 psi
17 bar, 1.7 MPa
Sound pressure
86 dBA at 100 psi
7 bar, 0.7 MPa
Sound power
98 dBA at 100 psi
7 bar, 0.7 MPa
Maximum Storage Time
5 years (To maintain original performance, replace soft seals after 5 years of inactivity.)
5 years (To maintain original performance, replace soft seals after 5 years of inactivity.)
Maximum Lifetime
Indefinite with recommended maintenance and periodic rebuilds for critical parts.
Indefinite with recommended maintenance and periodic rebuilds for critical parts.
Power Efficiency Factor (XP70)
75 cu. ft compressed air/1 gallon sprayed material at 100 psi
2.12 m³ compressed air/1 liter sprayed material at 7 bar (0.7 MPa)
Air consumption per 1 gallon (3.78 l) of flow
XP70
75 scfm at 100 psi/gpm (2.12 m³/min at 7 bar, 0.7 MPa)
75 scfm at 100 psi/gpm (2.12 m³/min at 7 bar, 0.7 MPa)
XP50
60 scfm at 100 psi/gpm (1.7 m³/min at 7 bar, 0.7 MPa)
60 scfm at 100 psi/gpm (1.7 m³/min at 7 bar, 0.7 MPa)
XP35
50 scfm at 100 psi/gpm (1.42 m³/min at 7 bar, 0.7 MPa)
50 scfm at 100 psi/gpm (1.42 m³/min at 7 bar, 0.7 MPa)
Filtration
Air inlet filtration
40-micron filter/separator included
40-micron filter/separator included
XP pump outlets
30 mesh
30 mesh
XTR Spray Gun
60 mesh
60 mesh
Fluid Viscosity Range
Gravity feed with 7 gallon (26 liter) hoppers
200 to 20,000 cps (pourable)
200 to 20,000 cps (pourable)
Pressure feed
Any viscosity that will not require feed pressure more than 15% of outlet pressure
Any viscosity that will not require feed pressure more than 15% of outlet pressure
Environmental Rating (Indoor/outdoor)
Hazardous Areas
EX II 2 G c IIA T2, NOTE: XP-h pump packages (284xxx) are not Ex rated.
EX II 2 G c IIA T2, NOTE: XP-h pump packages (284xxx) are not Ex rated.
Ambient Temperature Range
Operating
40-130°F
4-54°C
Storage
30-160°F
-1-71°C
Maximum Fluid Temperature
160°F
71°C
Wetted materials
Housings and manifolds
Carbon steel with electroless nickel plating
Carbon steel with electroless nickel plating
Miscellaneous parts
Plated carbon steel, stainless steels, carbide, acetal, UHM-WPE, nylon, PTFE solvent resistant plastics
Plated carbon steel, stainless steels, carbide, acetal, UHM-WPE, nylon, PTFE solvent resistant plastics
Pump packings
Carbon filled PTFE, proprietary UHMWPE
Carbon filled PTFE, proprietary UHMWPE
Flush pump suction tube
Aluminum
Aluminum
Hoses
Nylon core
Nylon core
Weight
Full XP35, XP50, or XP70 System with heaters, solvent flush pump, and hoppers
575 lb
261 kg
Full XP-h System with heaters, solvent flush pump, and hoppers
600 lb
273 kg
Bare XP35, XP50, or XP70 system with no heaters, solvent flush pump, or hoppers
425 lb
193 kg
Bare XP-h System with no heaters, solvent flush pump, or hoppers
450 lb
204 kg
XP35, XP50, or XP70 Pump only
286 lb
130 kg
XP-h Pump only
290 lb
132 kg