Graco Inc.

ProMix 2KS 配比系统  电子双组份配比系统

此款电子配比系统为各种溶剂型、水性和酸固化材料提供精确和可靠的电子配比。

购买地点小帮手咨询信息

Graco 的双组份和三组份配比系统为各种溶剂型、水性和酸固化材料提供精确和可靠的电子配比。 从入门级到升级型,ProMix 2KS 和 3KS 均具有高适应性和高效率。

  • 保证高精度配比
  • 提供关键过程变量反馈
  • 内置系统保护装置
  • 有效的换色解决方案
  • 高效的材料使用记录和报告

Graco has specific ProMix proportioners that are designed to manage tough acid catalyst applications like cabinetry and bar counter tops. The corrosion resistance fluid section, plus the smart fluid plate with 316 and 17-4 SST catalyst sections, can easily handle strong acid catalysts. 

ProMix 2KS Wall Panel, 50 cc
  • 手动和自动配置
  • 防爆流体盘可轻松整合至危险区内
  • 单色或多色色漆及催化剂
  • 精确配比,确保上乘涂装品质
  • 编程简单,可快速设置并实现高效过程控制
  • 高级 Web 界面提供统一的系统管理和报告

手册

ProMix 2KS Manual System
Maximum working air pressure
100 psi
7.0 bar, 0.7 MPa
Air supply
75–100 psi
5.2–7.0 bar, 0.5–0.7 MPa
Air filter inlet size
3/8 npt(f)
3/8 npt(f)
Air filtration for air logic and purge air (Graco-supplied)
5 micron (minimum) filtration required; clean and dry air
5 micron (minimum) filtration required; clean and dry air
Air filtration for atomizing air (user-supplied)
30 micron (minimum) filtration required; clean and dry air
30 micron (minimum) filtration required; clean and dry air
Mixing ratio range
0.1:1–50:1
0.1:1–50:1
Fluids handled
one or two component: solvent and waterborne paints, polyurethanes, epoxies, acid catalyzed varnishes, moisture sensitive isocyanates
one or two component: solvent and waterborne paints, polyurethanes, epoxies, acid catalyzed varnishes, moisture sensitive isocyanates
Viscosity range of fluid
20–5000 cps
20–5000 cps
Fluid filtration (user-supplied)
100 mesh minimum
100 mesh minimum
External power supply requirements
85–250 Vac, 50/60 Hz, 2 amps maximum draw, 15 amp maximum circuit breaker required, 8 to 14 AWG power supply wire gauge
85–250 Vac, 50/60 Hz, 2 amps maximum draw, 15 amp maximum circuit breaker required, 8 to 14 AWG power supply wire gauge
Operating temperature range
41–122°F
5–50°C
Environmental conditions rating
indoor use, pollution degree (2), installation category II
indoor use, pollution degree (2), installation category II
Wetted parts
303 and 304 stainless steel, Tungsten carbide (with nickel binder), perfluoroelastomer, PTFE
303 and 304 stainless steel, Tungsten carbide (with nickel binder), perfluoroelastomer, PTFE
Maximum fluid working pressure
Base system
4000 psi
280 bar, 28 MPa
Low pressure color change
300 psi
21 bar, 2.1 MPa
High pressure color change
3000 psi
210 bar, 21 MPa
Coriolis Meter
2300 psi
161 bar, 16.1 MPa
Fluid Flow Rate Range
G3000, G250 Meter
0.02–1.00 gpm
75–3800 cc/min
G3000HR, G250HR Meter
0.01–0.50 gpm
38–1900 cc/min
Coriolis Meter
0.005–1.00 gpm
20–3800 cc/min
S3000 Solvent Meter (accessory)
0.01–0.50 gpm
38–1900 cc/min
Fluid Porting
Flow Meter Fluid Inlet
1/4 npt(f)
1/4 npt(f)
Dose Valve/Color Valve Adapter Inlets
1/4 npt(f)
1/4 npt(f)
Fluid Outlet Size (static mixer)
1/4 npt(f)
1/4 npt(f)
Noise Level
Sound pressure level
below 70 dBA
below 70 dBA
Sound power level
below 85 dBA
below 85 dBA

ProMix 2KS Automatic System
Maximum working air pressure
100 psi
7.0 bar, 0.7 MPa
Air supply
75–100 psi
5.2–7.0 bar, 0.5–0.7 MPa
Air filter inlet size
3/8 npt(f)
3/8 npt(f)
Air filtration for air logic and purge air (Graco-supplied)
5 micron (minimum) filtration required; clean and dry air
5 micron (minimum) filtration required; clean and dry air
Air filtration for atomizing air (user-supplied)
30 micron (minimum) filtration required; clean and dry air
30 micron (minimum) filtration required; clean and dry air
Mixing ratio range
0.1:1–50:1
0.1:1–50:1
On-ratio accuracy
up to +/- 1%, user selectable
up to +/- 1%, user selectable
Fluids handled
one or two component: solvent and waterborne paints, polyurethanes, epoxies, acid catalyzed varnishes, moisture sensitive isocyanates
one or two component: solvent and waterborne paints, polyurethanes, epoxies, acid catalyzed varnishes, moisture sensitive isocyanates
Viscosity range of fluid
20–5000 cps
20–5000 cps
Fluid filtration (user-supplied)
100 mesh minimum
100 mesh minimum
External power supply requirements
85–250 Vac, 50/60 Hz, 2 amps maximum draw, 15 amp maximum circuit breaker required, 8 to 14 AWG power supply wire gauge
85–250 Vac, 50/60 Hz, 2 amps maximum draw, 15 amp maximum circuit breaker required, 8 to 14 AWG power supply wire gauge
Operating temperature range
41–122°F
5–50°C
Environmental conditions rating
indoor use, pollution degree (2), installation category II
indoor use, pollution degree (2), installation category II
Wetted parts
303 and 304 stainless steel, Tungsten carbide (with nickel binder), perfluoroelastomer, PTFE
303 and 304 stainless steel, Tungsten carbide (with nickel binder), perfluoroelastomer, PTFE
Maximum fluid working pressure
Base system
4000 psi
275.8 bar, 27.58 MPa
Low pressure color change
300 psi
20.6 bar, 2.07 MPa
Coriolis Meter
2300 psi
158.6 bar, 15.86 MPa
RoboMix system
190 psi
13.1 bar, 1.31 MPa
Flow control
190 psi
13.1 bar, 1.31 MPa
Fluid Flow Rate Range
G3000, G250 Meter
0.02–1.00 gpm
75–3800 cc/min
G3000HR, G250HR Meter
0.01–0.50 gpm
38–1900 cc/min
Coriolis Meter
0.005–1.00 gpm
20–3800 cc/min
S3000 Solvent Meter (accessory)
0.01–0.50 gpm
38–1900 cc/min
Fluid Porting
Flow Meter Fluid Inlet
1/4 npt(f)
1/4 npt(f)
Dose Valve/Color Valve Adapter Inlets
1/4 npt(f)
1/4 npt(f)
Fluid Outlet Size (static mixer)
1/4 npt(f)
1/4 npt(f)
Noise Level
Sound pressure level
below 70 dBA
below 70 dBA
Sound power level
below 85 dBA
below 85 dBA