ProMix 3KS Proportioners Electronic Plural Component Proportioning Systems
Purchase with a ProMix 2KS system or upgrade an existing 2KS system
Graco's two- and three-component proportioners offer precise and reliable electronic plural component proportioners for a broad range of solventborne, waterborne, and acid catalyzed materials. From entry level to upgraded applications, the ProMix 2KS and 3KS systems provide flexibility and increased efficiency.
- Offers the highest degree of ratio assurance
- Provides critical process variable feedback
- Built in system safeguards
- Effective color change solution
- Efficient material tracking and reporting
Graco has specific ProMix proportioners that are designed to manage tough acid catalyst applications like cabinetry and bar counter tops. The corrosion resistance fluid section, plus the smart fluid plate with 316 and 17-4 SST catalyst sections, can easily handle strong acid catalysts.
- Manual and automatic configurations
- Intrinsically safe fluid panels easily integrate into hazardous areas
- Single- or multi-color and catalysts
- Accurate ratio assurance for superior finish quality
- Simple programming allows fast set up and efficient process control
- Advanced web interface provides consolidated system management and reporting
Príručky
- 313882F, Manual, ProMix 3KS Operation for Manual Systems, English [iné jazyky]
- 313885F, ProMix 3KS Operation Manual, for Automatic Systems, English [iné jazyky]
- 313883C, ProMix 3KS Repair-Parts Manual, US English [iné jazyky]
- 313881B, ProMix 3KS Installation Manual, for Manual and Automatic Systems, Installation, English [iné jazyky]
- 313386F, Manual, ProMix® 2KS/3KS Web Interfaces, Instruction Manual, English [iné jazyky]
- 312784H, Manual, Gun Flush Box Kit, Instructions-Parts, English [iné jazyky]
- 312781H, Manual, Fluid Mix Manifold Instructions-Parts, English [iné jazyky]
- 312787H, Manual, Color Change Module Kits, Instructions and Parts, English [iné jazyky]
- 406719B, 15T632 Air Flow Switch Kit, Instructions, English (Len anglicky)
- 406715C, Instruction Form for Injection Kit 15U955, English [iné jazyky]
- 312786J - Dump Valve and Third Flush Valve Kits Instructions-Parts Manual, English [iné jazyky]
- 406799A, 15V256 Automatic Upgrade Kit, Instructions/Parts, English (Len anglicky)
- 406799A, 15V256 Automatic Upgrade Kit, Instructions/Parts, English (Len anglicky)
- 406804C, Instruction Form for Integrator Kit 24B618 (100cc) English (Len anglicky)
- 406713B, Dispense Valve Acid Kit, Instructions-Parts, English [iné jazyky]
- 406800B, 15V825 Discrete I/O Board Kit, Instructions/Parts, English [iné jazyky]
- 312782J, Air Actuated Dispense Valve Instruction-Parts Manual, English [iné jazyky]
- 312783E - Color and Catalyst Change Valves Instruction Manual, English [iné jazyky]
- 312783E - Color and Catalyst Change Valves Instruction Manual, English [iné jazyky]
- 312785D, Network Communication Kits Instruction-Parts Manual, English [iné jazyky]
- 313290A - 15V950 Floor Stand, English [iné jazyky]
- 313212B, Manual, 15V534 Gun Flush Box Interface Kit Instructions, English [iné jazyky]
- 313542F, Instructions, 15W034 Beacon Kit, 122193 Beacon Tower, English [iné jazyky]
- 199266S, ProMix 1KS, 2KS, 3KS, and Accessories, EU-Declaration of Conformity (Len anglicky)
- 199310D, Module, Gateway Communication & AWI, ProMix 2KS and 3KS , Informer Power Supply, 318-162 EC-Declaration of Conformity (European Community) English (Len anglicky)
313885F, ProMix 3KS Operation Manual, for Automatic Systems, English
313881B, ProMix 3KS Installation Manual, for Manual and Automatic Systems, Installation, English
313386F, Manual, ProMix® 2KS/3KS Web Interfaces, Instruction Manual, English
312787H, Manual, Color Change Module Kits, Instructions and Parts, English
406715C, Instruction Form for Injection Kit 15U955, English
312786J - Dump Valve and Third Flush Valve Kits Instructions-Parts Manual, English
406713B, Dispense Valve Acid Kit, Instructions-Parts, English
406800B, 15V825 Discrete I/O Board Kit, Instructions/Parts, English
312785D, Network Communication Kits Instruction-Parts Manual, English
313290A - 15V950 Floor Stand, English
313542F, Instructions, 15W034 Beacon Kit, 122193 Beacon Tower, English
Dokumenty
- 339996ENEU ProMix™ 2KS - Two-Component Electronic Proportioning System [iné jazyky]
- 344807ENEU ProMix 3KS [iné jazyky]
- 345099EN-F Acid Catalyst for ProMix Proportioners (Len anglicky)
- 345101EN Finishing Automation Equipment Overview [iné jazyky]
- 344880ENEU ProControl™ 1KS [iné jazyky]
- Viscosity Control with ProMix 3KS (Len anglicky)
- 3KS CARC Application (Len anglicky)
- 2KS Waterborne Urethane (Len anglicky)
339996ENEU ProMix™ 2KS - Two-Component Electronic Proportioning System
344807ENEU ProMix 3KS
345101EN Finishing Automation Equipment Overview
ProMix 3KS Manual System | |
Maximum working air pressure |
100 psi
7.0 bar, 0.7 MPa
|
Air supply |
75–100 psi
5.2–7.0 bar, 0.5–0.7 MPa
|
Air filter inlet size |
3/8 npt(f)
3/8 npt(f)
|
Air filtration for air logic and purge air (Graco-supplied) |
5 micron (minimum) filtration required; clean and dry air
5 micron (minimum) filtration required; clean and dry air
|
Air filtration for atomizing air (user-supplied) |
30 micron (minimum) filtration required; clean and dry air
30 micron (minimum) filtration required; clean and dry air
|
Mixing ratio range |
Stage 1 (A:B): 0.1:1–50:1, Stage 2 (A+B:C): 0.1:1–50:1
Stage 1 (A:B): 0.1:1–50:1, Stage 2 (A+B:C): 0.1:1–50:1
|
On-ratio accuracy |
up to +/- 1%, user selectable
up to +/- 1%, user selectable
|
Fluids handled |
one or two component: solvent and waterborne paints, polyurethanes, epoxies, acid catalyzed varnishes, moisture sensitive isocyanates
one or two component: solvent and waterborne paints, polyurethanes, epoxies, acid catalyzed varnishes, moisture sensitive isocyanates
|
Viscosity range of fluid |
20–5000 cps
20–5000 cps
|
Fluid filtration (user-supplied) |
100 mesh minimum
100 mesh minimum
|
External power supply requirements |
85–250 Vac, 50/60 Hz, 2 amps maximum draw, 15 amp maximum circuit breaker required, 8 to 14 AWG power supply wire gauge
85–250 Vac, 50/60 Hz, 2 amps maximum draw, 15 amp maximum circuit breaker required, 8 to 14 AWG power supply wire gauge
|
Operating temperature range |
41–122°F
5–50°C
|
Environmental conditions rating |
indoor use, pollution degree (2), installation category II
indoor use, pollution degree (2), installation category II
|
Wetted parts |
303 and 304 stainless steel, Tungsten carbide (with nickel binder), perfluoroelastomer, PTFE
303 and 304 stainless steel, Tungsten carbide (with nickel binder), perfluoroelastomer, PTFE
|
Maximum fluid working pressure | |
Base system |
3000 psi
210 bar, 21 MPa
|
Low pressure color change |
300 psi
21 bar, 2.1 MPa
|
High pressure color change |
3000 psi
210 bar, 21 MPa
|
Coriolis Meter |
2300 psi
161 bar, 16.1 MPa
|
Fluid Flow Rate Range | |
G3000, G250 Meter |
0.02–1.00 gpm
75–3800 cc/min
|
G3000HR, G250HR Meter |
0.01–0.50 gpm
38–1900 cc/min
|
Coriolis Meter |
0.005–1.00 gpm
20–3800 cc/min
|
S3000 Solvent Meter (accessory) |
0.01–0.50 gpm
38–1900 cc/min
|
Fluid Porting | |
Flow Meter Fluid Inlet |
1/4 npt(f)
1/4 npt(f)
|
Dose Valve/Color Valve Adapter Inlets |
1/4 npt(f)
1/4 npt(f)
|
3KS Fluid Station |
1/4 npt(m)
1/4 npt(m)
|
Fluid Outlet Size (static mixer) |
1/4 npt(f)
1/4 npt(f)
|
Noise Level | |
Sound pressure level |
below 70 dBA
below 70 dBA
|
Sound power level |
below 85 dBA
below 85 dBA
|
ProMix 3KS Automatic System | |
Maximum working air pressure |
100 psi
7.0 bar, 0.7 MPa
|
Air supply |
75–100 psi
5.2–7.0 bar, 0.5–0.7 MPa
|
Air filter inlet size |
3/8 npt(f)
3/8 npt(f)
|
Air filtration for air logic and purge air (Graco-supplied) |
5 micron (minimum) filtration required; clean and dry air
5 micron (minimum) filtration required; clean and dry air
|
Air filtration for atomizing air (user-supplied) |
30 micron (minimum) filtration required; clean and dry air
30 micron (minimum) filtration required; clean and dry air
|
Mixing ratio range |
Stage 1 (A:B): 0.1:1–50:1, Stage 2 (A+B:C): 0.1:1–50:1
Stage 1 (A:B): 0.1:1–50:1, Stage 2 (A+B:C): 0.1:1–50:1
|
On-ratio accuracy |
up to +/- 1%, user selectable
up to +/- 1%, user selectable
|
Fluids handled |
one or two component: solvent and waterborne paints, polyurethanes, epoxies, acid catalyzed varnishes, moisture sensitive isocyanates
one or two component: solvent and waterborne paints, polyurethanes, epoxies, acid catalyzed varnishes, moisture sensitive isocyanates
|
Viscosity range of fluid |
20–5000 cps
20–5000 cps
|
Fluid filtration (user-supplied) |
100 mesh minimum
100 mesh minimum
|
External power supply requirements |
85–250 Vac, 50/60 Hz, 2 amps maximum draw, 15 amp maximum circuit breaker required, 8 to 14 AWG power supply wire gauge
85–250 Vac, 50/60 Hz, 2 amps maximum draw, 15 amp maximum circuit breaker required, 8 to 14 AWG power supply wire gauge
|
Operating temperature range |
41–122°F
5–50°C
|
Environmental conditions rating |
indoor use, pollution degree (2), installation category II
indoor use, pollution degree (2), installation category II
|
Wetted parts |
303 and 304 stainless steel, Tungsten carbide (with nickel binder), perfluoroelastomer, PTFE
303 and 304 stainless steel, Tungsten carbide (with nickel binder), perfluoroelastomer, PTFE
|
Maximum fluid working pressure | |
Base system |
3000 psi
210 bar, 21 MPa
|
Low pressure color change |
300 psi
21 bar, 2.1 MPa
|
High pressure color change |
3000 psi
210 bar, 21 MPa
|
Coriolis Meter |
2300 psi
161 bar, 16.1 MPa
|
Fluid Flow Rate Range | |
G3000, G250 Meter |
0.02–1.00 gpm
75–3800 cc/min
|
G3000HR, G250HR Meter |
0.01–0.50 gpm
38–1900 cc/min
|
Coriolis Meter |
0.005–1.00 gpm
20–3800 cc/min
|
S3000 Solvent Meter (accessory) |
0.01–0.50 gpm
38–1900 cc/min
|
Fluid Porting | |
Flow Meter Fluid Inlet |
1/4 npt(f)
1/4 npt(f)
|
Dose Valve/Color Valve Adapter Inlets |
1/4 npt(f)
1/4 npt(f)
|
3KS Fluid Station |
1/4 npt(m)
1/4 npt(m)
|
Fluid Outlet Size (static mixer) |
1/4 npt(f)
1/4 npt(f)
|
Noise Level | |
Sound pressure level |
below 70 dBA
below 70 dBA
|
Sound power level |
below 85 dBA
below 85 dBA
|
-
Poľnohospodárske stroje – výroba
-
Príprava farieb
-
Striekacie kabíny
-
Nátery odolné voči chemikáliám
-
Automobilová elektronika
-
Spotrebná elektronika
-
Výroba elektroniky
-
Výroba a povrchová úprava nábytku
-
Výroba a všeobecné povrchové úpravy kovov
-
Architektonické úpravy a tvarovanie
-
Železnice
-
Kamiónová doprava
-
Vozové parky
-
Letectvo a kozmonautika – povrchová úprava
-
Drevársky a drevospracujúci priemysel
-
Výroba ťažkých strojov
Príslušenstvo
Súvisiace produkty
-
ProControl 1KE
Manage both fluids & air pressure to lock in precise spray parameters & improve spray performance
-
ProMix 2KE Proportioners
Compact, entry-level proportioner available in pump and metered versions for all spray techno...
-
ProMix 2KS Proportioners
Electronic proportioner for a broad range of solventborne, waterborne, and acid catalyzed mat...
-
ProMix PD2K Proportioners
100% Positive Displacement Technology for accurate mix ratios and consistent performance