QUANTM i120
QUANTM i120, 2"NPT, Aluminum Electric Diaphragm Pump, 200-240 V, AL Center, SA Seat, PT Ball, PS Diaphragm
Part Number: TE120-0164
QUANTM i120
QUANTM i120, 2"NPT, Aluminum Electric Diaphragm Pump, 200-240 V, AL Center, SA Seat, PT Ball, PS Diaphragm
Part Number: TE120-0164
If you’re not finding the information you need, ask one of our experts.
Ask an ExpertFeatures
Product BrochureThe all-aluminum fluid section is specifically designed to be abrasion-resistant while also providing mild corrosion resistance. With up to 8x more continuous torque at low speeds than conventional motors, this general-purpose electric pump is an energy-saving workhorse that is ideal for sump evacuation applications as well as applications involving the evacuation of petroleum products (new and waste oils) and evacuation of solvents. This powerful new pump delivers a higher level of reliability to minimize downtime while the plug-and-play design makes it easy to drop into any production line without additional investment or infrastructure rework. Not for use with halogenated hydrocarbons.
- Revolutionary Design
- Replace existing air operated pumps with electric pump technology that stalls under pressure and includes AutoPrime feature
- Compact and efficient electric drive removes the gearbox providing a comparable footprint to a pneumatic diaphragm pump
- Up to 80% reduction in energy consumption compared to pneumatic pumps, reducing operating costs and providing a quick investment payback
- Quiet operation reduces plant noise and improves employee safety and health
- Smart pump control provides more accurate flow set points and built-in I/O
- Efficient Electric Motor
- Powder-coated aluminum electric drive
- 240 VAC 3φ motor with 15 ft flying leads
- CID1 Groups C,D,T4 Zone 1 AEx d b IIB T4 Gb hazardous location approval
- Materials of Construction
- Aluminum fluid section with NPT end port
- Internal components include PTFE seat, PTFE ball, PTFE/Santoprene 2-piece diaphragm and PTFE manifold o-ring
Specifications & Documents
Technical Specifications
Convert to MetricApplication | Chemical Processing, Paints and Coatings, Waste Water, General Fluid Transfer |
---|---|
Ball Material | PTFE |
Center Section Material | Aluminum |
Configuration Code | QTE-ALFC3SAPTPSPTA100 |
Connection Type | NPT |
Construction | PTFE, PTFE/Santoprene 2-Piece |
Cord Length (ft) | 15 |
Diaphragm Material | PTFE/Santoprene 2-Piece |
Fluid Inlet Size (in) | 2 |
Fluid Inlet Thread Gender | Female |
Fluid Inlet Thread Type | NPT |
Fluid Outlet Size (in) | 2 |
Fluid Outlet Thread Gender | Female |
Fluid Outlet Thread Type | NPT |
Fluid Passage Size (in) | 2 |
Fluid Passage Size (mm) | 51 |
Fluid Section | Aluminum, End Port, NPT |
Fluid Section Material | Aluminum |
Hazardous Location Approval | Class 1, Division 1, ATEX, IECEx |
Manifold Configuration | End Port |
Manifold O-Ring Material | PTFE |
Maximum Ambient Temperature (°F) | 104 |
Maximum Amperage (A) | 7.5 |
Maximum Flow Rate (GPM) | 120 |
Maximum Fluid Operating Temperature (°C) | 82 |
Maximum Fluid Operating Temperature (°F) | 180 |
Maximum Fluid Pressure (psi) | 60 |
Maximum Solid Size (in) | 0.25 |
Minimum Fluid Operating Temperature (°C) | -40 |
Minimum Fluid Operating Temperature (°F) | -40 |
Model | QUANTM |
Motor Type | Electric Drive |
Overall Height (in) | 23.6 |
Seat Material | PTFE |
Series | i120 |
Type | Electric Diaphragm Pump |
Voltage (V ac) | 200-240 VAC 3Ph |
Weight (lb) | 99 |
Application | Chemical Processing, Paints and Coatings, Waste Water, General Fluid Transfer |
Ball Material | PTFE |
Center Section Material | Aluminum |
Configuration Code | QTE-ALFC3SAPTPSPTA100 |
Connection Type | NPT |
Construction | PTFE, PTFE/Santoprene 2-Piece |
Cord Length (m) | 4.57 |
Diaphragm Material | PTFE/Santoprene 2-Piece |
Fluid Inlet Size (in) | 2 |
Fluid Inlet Size (mm) | 51 |
Fluid Inlet Thread Gender | Female |
Fluid Inlet Thread Type | NPT |
Fluid Outlet Size (in) | 2 |
Fluid Outlet Size (mm) | 50.8 |
Fluid Outlet Thread Gender | Female |
Fluid Outlet Thread Type | NPT |
Fluid Passage Size (in) | 2 |
Fluid Passage Size (mm) | 51 |
Fluid Section | Aluminum, End Port, NPT |
Fluid Section Material | Aluminum |
Hazardous Location Approval | Class 1, Division 1, ATEX, IECEx |
Manifold Configuration | End Port |
Manifold O-Ring Material | PTFE |
Maximum Ambient Temperature (°C) | 40 |
Maximum Amperage (A) | 7.5 |
Maximum Flow Rate (L/min) | 454 |
Maximum Fluid Operating Temperature (°C) | 82 |
Maximum Fluid Operating Temperature (°F) | 180 |
Maximum Fluid Pressure (bar) | 4.14 |
Maximum Fluid Pressure (kPa) | 414 |
Maximum Fluid Pressure (psi) | 60 |
Maximum Solid Size (mm) | 6.4 |
Minimum Fluid Operating Temperature (°C) | -40 |
Minimum Fluid Operating Temperature (°F) | -40 |
Model | QUANTM |
Motor Type | Electric Drive |
Seat Material | PTFE |
Series | i120 |
Type | Electric Diaphragm Pump |
Voltage (V ac) | 200-240 VAC 3Ph |
Product Manuals
Sales Literature
Certifications
Repair Parts
Part No. | Description |
---|---|
D0F010 | 2-inch PTFE Check Ball Kit |
D0F400 | 2-inch 17-4PH Stainless Steel Seat Kit |
24F399 | PTFE/Santoprene 2-Piece Diaphragm Kit for 2-inch Pump |
26B352 | 2-inch PTFE Seal Kit |
25F124 | QUANTM i/h120 Rotor Kit |
25F103 | QUANTM i-Series Pump Control Knob for Hazardous Location Industrial Pump Models |
25V133 | QUANTM i120 Stator Cap Kit |
2001045 | Power Cord for Hazardous Location F-3 Motor Industrial QUANTM Pumps |