QUANTM h120

QUANTM h120, 2"Hygienic DIN, FG SST Electric Diaphragm Pump, 200-240 V, FEP AL Center, SS Seat, FK Ball, FK Diaphragm

Part Number: HE120-0541

product image

QUANTM h120

QUANTM h120, 2"Hygienic DIN, FG SST Electric Diaphragm Pump, 200-240 V, FEP AL Center, SS Seat, FK Ball, FK Diaphragm

Part Number: HE120-0541

QUANTM isn’t just another electric pump: it’s a game-changer. QUANTM features a revolutionary electric motor design that will reduce operational costs and delivers the reliability to keep your production lines running. With multiple fluid path options containing different materials of construction, ... More Info
Questions About this Product?

If you’re not finding the information you need, ask one of our experts.

Ask an Expert

Features

Product Brochure
QUANTM isn’t just another electric pump: it’s a game-changer. QUANTM features a revolutionary electric motor design that will reduce operational costs and delivers the reliability to keep your production lines running. With multiple fluid path options containing different materials of construction, QUANTM is ideal for most fluid applications as a highly reliable drop-in replacement for your current less-efficient pneumatic pumps or a perfect fit for greenfield construction. The unique self-priming, seal-less design delivers smooth and steady flow and is the only electric diaphragm pump on the market that stalls under pressure to reduce downtime caused by pump failures from clogged lines or closed valves. QUANTM is engineered to be quieter, more efficient and ultra-dependable while delivering energy savings that will go a long way to reinforcing your sustainability reputation. It’s time to rethink your pump strategy and elevate your bottom line by converting to a QUANTM electric pump.

Graco food-grade pumps are our most popular series for general food transfer. With their all-stainless-steel construction and 125 Ra surface finish, the groundbreaking new QUANTM food-grade electric pumps are certified to handle a wide range of food and beverage products and meet certification requirements for some personal care applications as well. From dressings, sauces, oils, syrups to soaps, creams and solvents, QUANTM electric food-grade pumps are a workhorse for almost any hygienic food-grade application. The powerful new electric motor delivers up to 8x more continuous torque at low speeds than conventional motors and the fast, easy plug-and-play installation allows you to easily replace existing pumps without additional investment or infrastructure rework.

  • Revolutionary Design
    • Replace existing air operated pumps with electric pump technology that stalls under pressure and includes AutoPrime feature
    • Compact and efficient electric drive removes the gearbox providing a comparable footprint to a pneumatic diaphragm pump
    • Up to 80% reduction in energy consumption compared to pneumatic pumps, reducing operating costs and providing a quick investment payback
    • Quiet operation reduces plant noise and improves employee safety and health
    • Smart pump control provides more accurate flow set points and built-in I/O
  • Efficient Electric Motor
    • FEP coated aluminum electric drive
    • 240 VAC 1Ph motor with 15 ft flying leads
    • ATEX Ex II 2 G EX dh IIB T4 Gb hazardous location approval
  • Materials of Construction
    • 125 Ra surface finish 316 stainless steel fluid section with hygienic DIN center port
    • Internal components include 316L stainless steel seat, FKM (Viton) ball, FKM (Viton) diaphragm and FKM (Viton) manifold o-ring
    • EN 3.1 material certification

Specifications & Documents

Technical Specifications

Convert to Metric
Application Food, Beverage, Personal Care, Pharmaceutical
Ball Material FKM (Viton)
Center Section Material FEP Coated Aluminum
Configuration Code QHE-FGFF4SSFKFKFKS140031
Connection Type Hygienic DIN
Construction 316L Stainless Steel, 316 Stainless Steel, FKM (Viton)
Cord Length (ft) 15
Diaphragm Material FKM (Viton)
Fluid Inlet Size (in) 2
Fluid Inlet Thread Type Hygienic DIN
Fluid Outlet Size (in) 2
Fluid Outlet Thread Type Hygienic DIN
Fluid Passage Size (in) 2
Fluid Passage Size (mm) 51
Fluid Section 316 Stainless Steel, End Port, Hygienic DIN
Fluid Section Material 316 Stainless Steel
Hazardous Location Approval ATEX, IECEx
Manifold Configuration End Port
Manifold O-Ring Material FKM (Viton)
Material Certification EN 1024:2004 Type 3.1 (Serialized)
Maximum Ambient Temperature (°F) 104
Maximum Amperage (A) 15
Maximum Flow Rate (GPM) 120
Maximum Fluid Operating Temperature (°C) 135
Maximum Fluid Operating Temperature (°F) 275
Maximum Fluid Pressure (psi) 60
Maximum Solid Size (in) 0.25
Minimum Fluid Operating Temperature (°C) -40
Minimum Fluid Operating Temperature (°F) -40
Model QUANTM
Motor Type Electric Drive
Overall Height (in) 25.95
Pump Size (in) 2
Seat Material 316 Stainless Steel
Series h120
Standards Met FDA Compliant Materials
Surface Finish 125 Ra
Type Electric Diaphragm Pump
Voltage (V ac) 200-240 VAC 1Ph
Weight (lb) 170
Application Food, Beverage, Personal Care, Pharmaceutical
Ball Material FKM (Viton)
Center Section Material FEP Coated Aluminum
Configuration Code QHE-FGFF4SSFKFKFKS140031
Connection Type Hygienic DIN
Construction 316L Stainless Steel, 316 Stainless Steel, FKM (Viton)
Cord Length (m) 4.57
Diaphragm Material FKM (Viton)
Fluid Inlet Size (in) 2
Fluid Inlet Size (mm) 51
Fluid Inlet Thread Type Hygienic DIN
Fluid Outlet Size (in) 2
Fluid Outlet Size (mm) 51
Fluid Outlet Thread Type Hygienic DIN
Fluid Passage Size (in) 2
Fluid Passage Size (mm) 51
Fluid Section 316 Stainless Steel, End Port, Hygienic DIN
Fluid Section Material 316 Stainless Steel
Hazardous Location Approval ATEX, IECEx
Manifold Configuration End Port
Manifold O-Ring Material FKM (Viton)
Material Certification EN 1024:2004 Type 3.1 (Serialized)
Maximum Ambient Temperature (°C) 40
Maximum Amperage (A) 15
Maximum Flow Rate (L/min) 454
Maximum Fluid Operating Temperature (°C) 135
Maximum Fluid Operating Temperature (°F) 275
Maximum Fluid Pressure (bar) 4.14
Maximum Fluid Pressure (kPa) 414
Maximum Fluid Pressure (psi) 60
Maximum Solid Size (mm) 6.35
Minimum Fluid Operating Temperature (°C) -40
Minimum Fluid Operating Temperature (°F) -40
Model QUANTM
Motor Type Electric Drive
Pump Size (mm) 51
Seat Material 316 Stainless Steel
Series h120
Standards Met FDA Compliant Materials
Surface Finish 125 Ra
Type Electric Diaphragm Pump
Voltage (V ac) 200-240 VAC 1Ph

Repair Parts

Part No. Description
D0F080 2-inch FKM (Viton) Check Ball Kit
26C568 2-inch 316 Stainless Steel Seat Kit
25V208 QUANTM i/h120 FKM (Viton) Diaphragm Kit
26B356 2-inch FKM (Viton) Seal Kit for FG Pump Models
25F124 QUANTM i/h120 Rotor Kit
25F105 QUANTM h-Series Pump Control Knob for Hazardous Location Hygienic Pump Models
25V134 QUANTM h120 Stator Cap Kit
19B823 Power Cord for Hazardous Location F-4 Motor QUANTM Pumps

GET HELP FROM A LOCAL DEALER

Showing dealers for

Have Questions? Let's Talk.

Call Support

Call Support

Monday–Friday
7:30 a.m.–5 p.m. Central Time

Email Support

Email Support

Find a Distributor

Find a Distributor

For local sales and service support

Graco